The impact of heating, ventilation, and air conditioning design features on the transmission of viruses, including the 2019 novel coronavirus: A systematic review of ventilation and coronavirus

PLOS Glob Public Health. 2022 Jul 5;2(7):e0000552. doi: 10.1371/journal.pgph.0000552. eCollection 2022.

Abstract

Aerosol transmission has been a pathway for the spread of many viruses. Similarly, emerging evidence has determined aerosol transmission for Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) and the resulting COVID-19 pandemic to be significant. As such, data regarding the effect of Heating, Ventilation, and Air Conditioning (HVAC) features to control and mitigate virus transmission is essential. A systematic review was conducted to identify and comprehensively synthesize research examining the effectiveness of ventilation for mitigating transmission of coronaviruses. A comprehensive search was conducted in Ovid MEDLINE, Compendex, Web of Science Core to January 2021. Study selection, data extraction, and risk of bias assessments were performed by two authors. Evidence tables were developed and results were described narratively. Results from 32 relevant studies showed that: increased ventilation rate was associated with decreased transmission, transmission probability/risk, infection probability/risk, droplet persistence, virus concentration, and increased virus removal and virus particle removal efficiency; increased ventilation rate decreased risk at longer exposure times; some ventilation was better than no ventilation; airflow patterns affected transmission; ventilation feature (e.g., supply/exhaust, fans) placement influenced particle distribution. Few studies provided specific quantitative ventilation parameters suggesting a significant gap in current research. Adapting HVAC ventilation systems to mitigate virus transmission is not a one-solution-fits-all approach. Changing ventilation rate or using mixing ventilation is not always the only way to mitigate and control viruses. Practitioners need to consider occupancy, ventilation feature (supply/exhaust and fans) placement, and exposure time in conjunction with both ventilation rates and airflow patterns. Some recommendations based on quantitative data were made for specific scenarios (e.g., using air change rate of 9 h-1 for a hospital ward). Other recommendations included using or increasing ventilation, introducing fresh air, using maximum supply rates, avoiding poorly ventilated spaces, assessing fan placement and potentially increasing ventilation locations, and employing ventilation testing and air balancing checks. Trial registration: PROSPERO 2020 CRD42020193968.

Grants and funding

This work is funded by a Canadian Institutes of Health Research (CIHR) Operating Grant: Canadian 2019 Novel Coronavirus (COVID-19) Rapid Research Funding Opportunity [https://webapps.cihr-irsc.gc.ca/decisions/p/project_details.html?applId=422567&lang=en] and Alberta Innovates. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Author LH is supported by a Canada Research Chair in Knowledge Synthesis and Translation. Authors BF and LZ are supported by the NSERC Discovery program.