Difficult removal after bronchial filling of an endobronchial Watanabe spigot with N-butyl-2-cyanoacrylate for intractable pneumothorax: A case report

Respirol Case Rep. 2023 Mar 21;11(4):e01126. doi: 10.1002/rcr2.1126. eCollection 2023 Apr.

Abstract

A 52-year-old man developed a right pneumothorax during treatment for COVID-19. In a previous case report concerning this patient, his recovery was achieved through implanting four endobronchial Watanabe spigots (EWS) in the right B1 and B3 in two phases and spraying N-butyl-2-cyanoacrylate (NBCA). One year later, EWS removal was planned. He was intubated under bronchoscopic guidance, and the right upper lobe was observed. The right B1 and B3 inlets were found to be covered with granuloma. Despite the presence of a nylon thread for easy retrieval and partial debridement of the granulation, removal of the implanted EWS in the right B1 and B3 using grasping forceps, basket forceps, and two types of balloons under fluoroscopic guidance was challenging. NBCA spraying is a possible cause of foreign body granuloma formation. Therefore, careful consideration of the indications for the combined EWS-NBCA procedure is necessary.

Keywords: N‐butyl‐2‐cyanoacrylate; endobronchial Watanabe spigot; foreign body granuloma.

Publication types

  • Case Reports