Cardiovascular diseases, in particular hypertension and hypercholesterolemia, are two of the main causes of death worldwide. These conditions are silent killer syndromes that need a variety of pharmacological treatments to be effectively controlled. This study introduces novel, environmentally friendly spectrophotometric techniques for the simultaneous determination of telmisartan (TMS) and rosuvastatin calcium (RVS) in their pharmaceutical dosage forms. For the simultaneous determination of the binary mixture, the suggested methods included the dual wavelength method (DWM) which utilizes mainly the absorbance difference at 233 nm and 253 for TMS determination and, the absorbance difference at 274 nm and 310 for RVS determination as the selected wavelengths for each drug is directly proportional to the drug of interest independent on the other interfering component. The Fourier-self deconvolutions method (FSDM) depends on compressing their bandwidth to resolve the overlap. Ratio difference spectrophotometric method (RDSM) that utilizes TMS 35 μg.mL-1 and RVS 20 μg.mL-1, respectively as divisors to produce the ratio spectra for each drug. Further manipulation of the produced ratio spectra was applied for the determination of the two drugs. Mean centering method (MCM) where a suitable wavelength range was chosen to exclusively use the informative portions and prevent experimental spectrum noises. The investigated methods showed good levels of detection and quantification together with excellent linearity. The suggested methods' greenness was evaluated using two different greenness evaluation tools, which showed that the methods were green in terms of several factors, including the safety of the chemicals, instruments, and waste. The validity of the methodologieswas investigated by resolving prepared laboratory mixtureswith varying TMS and RVS ratios. The standard addition method also assured the newly added methods. Finally, statistical analysis using the reported method did not reveal any appreciable differences in terms of accuracy and precision. The developed methods can be employed in quality control laboratories to ascertain the binary mixture due to their high precision and affordability.

Keywords: Dual-wavelength method; Fourier self-deconvolution method; Mean centering method; Ratio difference spectrophotometric method; Rosuvastatin calcium; Telmisartan.

MeSH terms

  • Pharmaceutical Preparations
  • Quality Control
  • Spectrophotometry* / methods

Substances

  • Pharmaceutical Preparations