Data adaptive regularization with reference tissue constraints for liver quantitative susceptibility mapping

Magn Reson Med. 2023 Aug;90(2):385-399. doi: 10.1002/mrm.29644. Epub 2023 Mar 17.

Abstract

Purpose: To improve repeatability and reproducibility across acquisition parameters and reduce bias in quantitative susceptibility mapping (QSM) of the liver, through development of an optimized regularized reconstruction algorithm for abdominal QSM.

Methods: An optimized approach to estimation of magnetic susceptibility distribution is formulated as a constrained reconstruction problem that incorporates estimates of the input data reliability and anatomical priors available from chemical shift-encoded imaging. The proposed data-adaptive method was evaluated with respect to bias, repeatability, and reproducibility in a patient population with a wide range of liver iron concentration (LIC). The proposed method was compared to the previously proposed and validated approach in liver QSM for two multi-echo spoiled gradient-recalled echo protocols with different acquisition parameters at 3T. Linear regression was used for evaluation of QSM methods against a reference FDA-approved R 2 $$ {R}_2 $$ -based LIC measure and R 2 $$ {R}_2^{\ast } $$ measurements; repeatability/reproducibility were assessed by Bland-Altman analysis.

Results: The data-adaptive method produced susceptibility maps with higher subjective quality due to reduced shading artifacts. For both acquisition protocols, higher linear correlation with both R 2 $$ {R}_2 $$ - and R 2 $$ {R}_2^{\ast } $$ -based measurements were observed for the data-adaptive method ( r 2 = 0 . 74 / 0 . 69 $$ {r}^2=0.74/0.69 $$ for R 2 $$ {R}_2 $$ , 0 . 97 / 0 . 95 $$ 0.97/0.95 $$ for R 2 $$ {R}_2^{\ast } $$ ) than the standard method ( r 2 = 0 . 60 / 0 . 66 $$ {r}^2=0.60/0.66 $$ and 0 . 79 / 0 . 88 $$ 0.79/0.88 $$ ). For both protocols, the data-adaptive method enabled better test-retest repeatability (repeatability coefficients 0.19/0.30 ppm for the data-adaptive method, 0.38/0.47 ppm for the standard method) and reproducibility across protocols (reproducibility coefficient 0.28 vs. 0.53ppm) than the standard method.

Conclusions: The proposed data-adaptive QSM algorithm may enable quantification of LIC with improved repeatability/reproducibility across different acquisition parameters as 3T.

Keywords: QSM; iron; liver; susceptibility.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, N.I.H., Extramural

MeSH terms

  • Abdomen
  • Brain / diagnostic imaging
  • Brain Mapping
  • Humans
  • Iron* / analysis
  • Liver / chemistry
  • Liver / diagnostic imaging
  • Magnetic Resonance Imaging* / methods
  • Reproducibility of Results