Abstract

Rationale: Poor adherence limits the effectiveness of continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea (OSA). A better understanding of CPAP adherence is needed to develop novel strategies to improve it. Objectives: To determine if the chronotype (morning, evening, or intermediate) of patients with OSA is associated with differences in CPAP adherence. If such an association exists, determine the mechanisms underlying this association. Methods: We performed a secondary analysis of the APPLES (Apnea Positive Pressure Long-term Efficacy Study) clinical trial. We assessed chronotype using the Morningness-Eveningness Questionnaire (MEQ) among participants randomized to the CPAP arm with daily adherence data (n = 469). Evening (MEQ ⩽ 41), intermediate (41 < MEQ < 59), and morning type (MEQ ⩾ 59) categories were the exposures. We modeled daily CPAP use (hours per night) over a 6-month period, using a linear mixed model, adjusted for covariates (e.g., age, sex, marital status). To assess mechanisms of the association, we performed mediation analyses using sleep duration, weekend catch-up sleep, depression, and other factors. Results: Most participants were obese men with severe OSA (body mass index of 32.3 ± 7.3 kg/m2, 65% male, and apnea-hypopnea index 39.8 ± 24.6/h). Participants were 44% morning, 47% intermediate, and 8% evening chronotype. Participants with the morning chronotype reported the shortest sleep duration on weekends (7.3 vs. 7.6 and 7.9 h/night) compared with the intermediate and evening types. Participants with the morning chronotype exhibited a 40-min/night higher CPAP use (P = 0.001) than persons with the intermediate chronotype. This relationship was mildly attenuated (32.8 min/night; P = 0.011) after adjustment for covariates. None of the selected factors (e.g., sleep duration, weekend catch-up sleep) exhibited a significant mediation effect. Conclusions: Morning chronotype is associated with a clinically meaningful increase in CPAP adherence compared with other chronotypes. Mechanisms of this association require further study. Chronotype may be a novel predictor of CPAP adherence. Clinical trial registered with www.clinicaltrials.gov (NCT00051363).

Keywords: CPAP; OSA; adherence; chronotype.

Publication types

  • Randomized Controlled Trial
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Body Mass Index
  • Chronotype*
  • Continuous Positive Airway Pressure
  • Female
  • Humans
  • Male
  • Patient Compliance
  • Sleep
  • Sleep Apnea, Obstructive* / complications
  • Sleep Apnea, Obstructive* / therapy

Associated data

  • ClinicalTrials.gov/NCT00051363