Endovascular repair in type A aortic dissection: Anatomical candidacy for currently manufactured stent grafts and conceptual valve-carrying devices for an Endo-Bentall procedure

Eur J Cardiothorac Surg. 2023 May 2;63(5):ezad085. doi: 10.1093/ejcts/ezad085.

Abstract

Objectives: Endovascular treatment has been suggested as an alternative for open surgery for type A aortic dissection, but current devices have severe anatomical limitations. This study assesses the computed tomography-based anatomical suitability of currently manufactured stent grafts as well as 2 embodiments of valve-carrying devices.

Methods: In a retrospective single-centre cohort of 200 consecutive ascending/arch operations between 2009 and 2018, a total of 112 patients with type A aortic dissections were identified and evaluated for endovascular candidacy based on the locations of the entries, the landing zone diameters/lengths and the supra-aortic vessel origins according to the anatomical instructions for use criteria of 6 commercially available (tubular, branched or fenestrated) stent grafts. Two suggested valve-carrying devices with inner branches or fenestrations for the coronary arteries and branches for the supra-aortic vessels were also evaluated.

Results: The anatomical feasibility for commercial stent grafts ranged from 4% to 21%. The main limitations were proximal landing zone diameter (considering oversizing <15%), length due to dilatation and an entry too close to the sinotubular junction. For the valve-carrying conduits, anatomical feasibility was between 31% and 80%, with the main limiting factors being the diameter of the aortic annulus and its distance to the coronary arteries.

Conclusions: The anatomical applicability of currently manufactured stent grafts for the treatment of type A aortic dissection is limited mainly by the absence of a suitable proximal landing zone in the ascending aorta and might substantially be improved by anchoring in the aortic annulus using a valve-carrying device that uses either fenestrations or branches for the coronary arteries.

Keywords: Endovascular aortic repair; Type A dissection; Valve-carrying conduit.

MeSH terms

  • Aortic Aneurysm, Thoracic* / surgery
  • Aortic Dissection*
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / methods
  • Endovascular Procedures* / methods
  • Humans
  • Prosthesis Design
  • Retrospective Studies
  • Stents
  • Treatment Outcome