Severe Hypersensitivity Reaction to Dermabond Prineo After Anterior Cervical Discectomy and Fusion: A Case Report

JBJS Case Connect. 2023 Mar 9;13(1). doi: 10.2106/JBJS.CC.22.00668. eCollection 2023 Jan 1.

Abstract

Case: A 68-year-old woman underwent an anterior cervical discectomy and fusion for cervical radiculopathy and subsequently developed a severe contact hypersensitivity reaction in response to Dermabond Prineo, beginning 10 days postoperatively. The Dermabond Prineo mesh was removed, and the patient was treated symptomatically with diphenhydramine, systemic steroids, and oral antibiotics, with complete resolution of her symptoms.

Conclusion: This is the first reported contact hypersensitivity reaction to Dermabond Prineo in the context of spine surgery. Surgeons should be able to recognize this presentation and treat this appropriately.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Cervical Vertebrae / surgery
  • Dermatitis, Contact*
  • Diskectomy / adverse effects
  • Female
  • Humans
  • Spinal Fusion* / adverse effects

Substances

  • octyl 2-cyanoacrylate