Screw-retained internal connection zirconia CAD-CAM abutments in single implant reconstructions: Results of a 1-year prospective case series study

J Prosthodont. 2023 Oct;32(8):679-688. doi: 10.1111/jopr.13674. Epub 2023 Mar 21.

Abstract

Purpose: To evaluate the clinical and radiographic outcomes of single-tooth implant restorations using one-piece, internally connected, screw-retained, computer-aided design and computer-aided manufactured monolithic zirconia restorations fabricated on regular diameter implants.

Material and methods: Following a 2-stage surgical procedure, 22 implants placed in anterior and posterior areas in 21 partially edentulous patients (mean age of 55 years; 9 males/12 females) were evaluated in terms of plaque index, pocket probing depth, bleeding on probing, level of oral hygiene (OH), signs of mucositis/peri-implantitis, esthetic score (ES), gingival zenith position (GZP), papilla index score, the thickness of peri-implant gingiva, radiographic marginal bone loss, and technical complications. Implants and restorations were prospectively followed from the insertion of the restoration (baseline), up to 12-months post-loading.

Results: A 100% implant survival rate resulted after loading; one implant was lost before loading. Clinically, patients performed an adequate OH, and tissues were kept healthy. Probing depth showed a slightly lower value at baseline compared to any follow-up examination (2.26 [0.94] at baseline vs. 2.53 [0.66] mm at 12 months). ES, GZP, and the thickness of the peri-implant gingiva improved throughout the course of the study. Radiographically, average marginal bone level (MBL) was 0.40 (0.40) mm after 1-year follow-up with no differences in average MBL at all time points. Technically, after 1 year of clinical function, neither abutment fracture nor any other serious complications occurred. Hence, prosthetic reconstruction survival rate was 100%.

Conclusions: Clinical outcomes of single-tooth implant restorations using internally connected, screw-retained, computer-aided design and computer-aided manufacturing monolithic zirconia abutments can be considered a reliable treatment alternative after 1-year clinical observation.

Keywords: dental implant; esthetics; marginal bone level; monolithic; outcomes; single implant restorations.

MeSH terms

  • Bone Screws
  • Computer-Aided Design
  • Crowns
  • Dental Abutments
  • Dental Implant-Abutment Design
  • Dental Implants*
  • Dental Implants, Single-Tooth*
  • Esthetics, Dental
  • Female
  • Humans
  • Male
  • Middle Aged
  • Zirconium

Substances

  • zirconium oxide
  • Dental Implants
  • Zirconium