Oculomotor fatigability with decrements of saccade and smooth pursuit for diagnosis of myasthenia gravis

J Neurol. 2023 May;270(5):2743-2755. doi: 10.1007/s00415-023-11611-7. Epub 2023 Mar 1.

Abstract

Background and objectives: As the efficacy of current diagnostic methods for myasthenia gravis (MG) remains suboptimal, there is ongoing interest in developing more effective diagnostic models. As oculomotor fatigability is one of the most common and diagnostic symptoms in MG, we aimed to investigate whether quantitative saccadic and smooth-pursuit fatigability analyses with video-oculography (VOG) are useful for diagnosis of MG.

Methods: A convenience cohort of 46 MG patients was recruited prospectively, including 35 with ocular and 11 with generalized MG (mean age, 50.9 ± 14.5 years; 17 females); 24 healthy controls (HCs) (mean age, 50.6 ± 16.3 years; 13 females) also were enrolled. Seventy-five repetitive saccades and smooth pursuits were recorded in ranges of 20° (horizontal plane) and 15° (vertical plane) using a three-dimensional VOG system. Based on the oculomotor range of the second saccade and smooth pursuit and the mean ranges of the last five of each, the estimated decrements (%) reflecting oculomotor fatigability were calculated.

Results: The baseline oculomotor ranges did not show significant difference between the MG and HCs groups. However, following repetitive saccades and pursuits, the oculomotor ranges were decreased substantially during the last five cycles compared to baseline in the MG group. No such decrements were observed in the HC group (p < 0.01, Mann-Whitney U test). Receiver operating characteristic (ROC) analysis revealed that repetitive vertical saccades yielded the best differentiation between the MG and HC groups, with a sensitivity of 78.3% and specificity of 95.8% when using a decrement with an amplitude of 6.4% as the cutoff.

Conclusion: This study presents an objective and reproducible method for measuring decrements of oculomotor ranges after repetitive saccadic and pursuit movements. Quantification of oculomotor fatigability using VOG could be a sensitive and specific diagnostic tool for MG and allows easy, cost-effective, accurate, and non-invasive measurements.

Classification of evidence: This study provides class III evidence that VOG-based quantification of saccadic and pursuit fatigability accurately identifies patients with MG.

Keywords: Fatigability; Generalized myasthenia gravis; Myasthenia gravis; Ocular myasthenia gravis; Oculomotor fatigability; Saccade; Smooth pursuit; Video-oculography.

MeSH terms

  • Adult
  • Aged
  • Eye Movements
  • Fatigue / diagnosis
  • Fatigue / etiology
  • Female
  • Humans
  • Middle Aged
  • Myasthenia Gravis* / diagnosis
  • Pursuit, Smooth
  • ROC Curve
  • Saccades*