What Is the Linear Accuracy of Regional Voxel-Based Registration for Orthognathic Surgery Landmarks?

J Oral Maxillofac Surg. 2023 May;81(5):546-556. doi: 10.1016/j.joms.2023.01.015. Epub 2023 Feb 21.

Abstract

Purpose: While regional voxel-based registration (R-VBR) has been shown to have excellent reproducibility and angular accuracy, there are limited data on the linear accuracy of R-VBR for common orthognathic surgery landmarks, or on whether angular accuracy correlates with linear accuracy. The purpose of this study was to estimate the linear accuracy of R-VBR for several skeletal landmarks commonly used in orthognathic surgical planning, and to measure the correlation between angular and linear discrepancies.

Materials and methods: This is a retrospective cross-sectional study of consecutive patients treated at a single center with nonsegmental LeFort I and bilateral sagittal split osteotomy surgery from January 2019 to November 2020. Cone beam computed tomography at the preoperative (T0) and immediate postoperative (T1) stages were analyzed to measure the postoperative positional changes of 11 orthognathic landmarks in 4 regions of interest (ROI) using R-VBR performed twice by two examiners. Pairwise correlation analysis and canonical correlation analysis were performed for the angular discrepancies (primary predictor variable) and the linear discrepancies (primary outcome variable) to measure the correlation between the two.

Results: In cone beam computed tomography analysis of 28 eligible subjects (16 males, 12 females; mean age 18.9 years, range 15 to 25), the mean absolute (MA) angular discrepancies ranged from 0.15° to 0.55°, while the corresponding MA linear discrepancies ranged from 0.05 to 0.41 mm. There was a strong correlation between angular and linear discrepancies that was statistically significant (P = .001 to .04, Spearman's rank correlation coefficient 0.38 to 0.87).

Conclusions: For nonsegmental LeFort I osteotomies and bilateral sagittal split osteotomy, R-VBR has excellent linear accuracy within a single voxel size (0.3 mm) for commonly used orthognathic landmarks in the maxillary and distal mandibular ROI. The MA linear discrepancy for the proximal mandibular segment ROI was greater than a single voxel size, with a maximum of 0.41 mm.