Printed Silk Microelectrode Arrays for Electrophysiological Recording and Controlled Drug Delivery

Adv Healthc Mater. 2023 Jul;12(17):e2202869. doi: 10.1002/adhm.202202869. Epub 2023 Mar 3.

Abstract

The use of soft and flexible bioelectronic interfaces can enhance the quality for recording cells' electrical activity by ensuring a continuous and intimate contact with the smooth, curving surfaces found in the physiological environment. This work develops soft microelectrode arrays (MEAs) made of silk fibroin (SF) films for recording interfaces that can also serve as a drug delivery system. Inkjet printing is used as a tool to deposit the substrate, conductive electrode, and insulator, as well as a drug-delivery nanocomposite film. This approach is highly versatile, as shown in the fabrication of carbon microelectrodes, sandwiched between a silk substrate and a silk insulator. The technique permits the development of thin-film devices that can be employed for in vitro extracellular recordings of HL-1 cell action potentials. The tuning of SF by applying an electrical stimulus to produce a permeable layer that can be used in on-demand drug delivery systems is also demonstrated. The multifunctional MEA developed here can pave the way for in vitro drug screening by applying time-resolved and localized chemical stimuli.

Keywords: additive manufacturing; cell recording; electrophysiology; inkjet; microelectrode arrays; microelectrodes; soft materials.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Drug Delivery Systems
  • Electric Conductivity
  • Fibroins*
  • Microelectrodes
  • Silk*

Substances

  • Silk
  • Fibroins