Fusion imaging of single-photon emission computed tomography and magnetic resonance lymphangiography for post-Fontan chylothorax

Radiol Case Rep. 2023 Feb 1;18(4):1471-1476. doi: 10.1016/j.radcr.2023.01.021. eCollection 2023 Apr.

Abstract

A preschool male patient with an extensive cardiac surgical history developed refractory chylothorax after a total cavopulmonary connection. Neither lymphoscintigraphy nor single-photon emission computed tomography (SPECT)/computed tomography could identify the lymphatic system leakage sites. Non-contrast heavy T2-weighted magnetic resonance lymphangiography (MRL) was performed to visualize the lymphatic system. Nevertheless, distinguishing lymphatic ducts from other watery structures of the patient remained difficult. Therefore, non-contrast MRL and SPECT images were fused. This hybrid diagnostic tool elucidated the pathophysiology of the prolonged chylothorax; pulmonary lymphatic perfusion syndrome and illustrated the anatomical connection of the thoracic duct and an abnormally dilated lymphatic network in the neck and left hilar regions. Subsequent intranodal lymphangiography with ethiodized oil confirmed these findings. SPECT/MRL may become an alternative modality for revealing the mechanism of prolonged chylothorax by visualizing the lymphatic system when dynamic contrast-enhanced magnetic resonance lymphangiography is unavailable.

Keywords: Cardiology; Chylothorax; Lymphography; MRI; Pediatrics; SPECT.

Publication types

  • Case Reports