Validation of automatically measured T1 map cortico-medullary difference (ΔT1) for eGFR and fibrosis assessment in allograft kidneys

PLoS One. 2023 Feb 15;18(2):e0277277. doi: 10.1371/journal.pone.0277277. eCollection 2023.

Abstract

MRI T1-mapping is an important non-invasive tool for renal diagnosis. Previous work shows that ΔT1 (cortex-medullary difference in T1) has significant correlation with interstitial fibrosis in chronic kidney disease (CKD) allograft patients. However, measuring cortico-medullary values by manually drawing ROIs over cortex and medulla (a gold standard method) is challenging, time-consuming, subjective and requires human training. Moreover, such subjective ROI placement may also affect the work reproducibility. This work proposes a deep learning-based 2D U-Net (RCM U-Net) to auto-segment the renal cortex and medulla of CKD allograft kidney T1 maps. Furthermore, this study presents a correlation of automatically measured ΔT1 values with eGFR and percentage fibrosis in allograft kidneys. Also, the RCM U-Net correlation results are compared with the manual ROI correlation analysis. The RCM U-Net has been trained and validated on T1 maps from 40 patients (n = 2400 augmented images) and tested on 10 patients (n = 600 augmented images). The RCM U-Net segmentation results are compared with the standard VGG16, VGG19, ResNet34 and ResNet50 networks with U-Net as backbone. For clinical validation of the RCM U-Net segmentation, another set of 114 allograft kidneys patient's cortex and medulla were automatically segmented to measure the ΔT1 values and correlated with eGFR and fibrosis. Overall, the RCM U-Net showed 50% less Mean Absolute Error (MAE), 16% better Dice Coefficient (DC) score and 12% improved results in terms of Sensitivity (SE) over conventional CNNs (i.e. VGG16, VGG19, ResNet34 and ResNet50) while the Specificity (SP) and Accuracy (ACC) did not show significant improvement (i.e. 0.5% improvement) for both cortex and medulla segmentation. For eGFR and fibrosis assessment, the proposed RCM U-Net correlation coefficient (r) and R-square (R2) was better correlated (r = -0.2, R2 = 0.041 with p = 0.039) to eGFR than manual ROI values (r = -0.19, R2 = 0.037 with p = 0.051). Similarly, the proposed RCM U-Net had noticeably better r and R2 values (r = 0.25, R2 = 0.065 with p = 0.007) for the correlation with the renal percentage fibrosis than the Manual ROI results (r = 0.3, R2 = 0.091 and p = 0.0013). Using a linear mixed model, T1 was significantly higher in the medulla than in the cortex (p<0.0001) and significantly lower in patients with cellular rejection when compared to both patients without rejection and those with humoral rejection (p<0.001). There was no significant difference in T1 between patients with and without humoral rejection (p = 0.43), nor between the types of T1 measurements (Gold standard manual versus automated RCM U-Net) (p = 0.7). The cortico-medullary area ratio measured by the RCM U-Net was significantly increased in case of cellular rejection by comparison to humoral rejection (1.6 +/- 0.39 versus 0.99 +/- 0.32, p = 0.019). In conclusion, the proposed RCM U-Net provides more robust auto-segmented cortex and medulla than the other standard CNNs allowing a good correlation of ΔT1 with eGFR and fibrosis as reported in literature as well as the differentiation of cellular and humoral transplant rejection. Therefore, the proposed approach is a promising alternative to the gold standard manual ROI method to measure T1 values without user interaction, which helps to reduce analysis time and improves reproducibility.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Allografts
  • Fibrosis
  • Humans
  • Kidney* / diagnostic imaging
  • Magnetic Resonance Imaging / methods
  • Renal Insufficiency, Chronic*
  • Reproducibility of Results

Grants and funding

This work was supported by grants from the Clinical Research Center of the Medicine Faculty of Geneva University and Geneva University Hospital as well as the Louis- Jeantet Foundations and the Swiss National Science Foundation (JPV grant 32003B_159714, IZCOZO_177140 / 1 and SDS grant PP00P3_127454). This work was supported in part by the Centre for Biomedical Imaging (CIBM) and the Swiss National Science Foundation for its financial support for the PRISMA MRI (R’Equip grants: SNF No 326030_150816). The funders had no role in study design data collection and analysis decision to publish or preparation of the manuscript.