Relationship between PaO2/FiO2 and delirium in intensive care: A cross-sectional study

J Intensive Med. 2022 Oct 1;3(1):73-78. doi: 10.1016/j.jointm.2022.08.002. eCollection 2023 Jan 31.

Abstract

Background: To investigate the relationship between partial pressure of oxygen (PaO2)/fraction of inspired oxygen (FiO2) and the probability of delirium in intensive care units (ICUs).

Methods: The investigation was a cross-sectional study that involved the collection of data from patients admitted to the Xiang Ya Hospital Cardiothoracic Surgical Care Unit and Comprehensive Intensive Care Unit from 01 September 2016 to 10 December 2016. Delirium was diagnosed using the simplified version of the Chinese Confusion Assessment Method (CAM) for the ICU. Demographic and medical data were obtained within 24 h of each patient admitted in the ICU. The PaO2/FiO2 of each patient was recorded 24 h after admission in the ICU. The patients were divided into three groups according to PaO2/FiO2 data : normal (PaO2/FiO2 ≥300 mmHg), slightly low (200 ≥PaO2/FiO2 <300 mmHg), and severely low (PaO2/FiO2 <200 mmHg). Baseline characteristics were compared in the three groups. Results of the unadjusted model, minimally adjusted model, and fully adjusted model are presented.

Results: A total of 403 participants were included in the study, of which 184 (45.7%) developed delirium. Age (P <0.001), Sequential Organ Failure Assessment (SOFA) score (P <0.001), Acute Physiology and Chronic Health Evaluation (APACHE) II score (P <0.001), mechanical ventilation time (P <0.001), history of hypertension (P=0.040), heart disease (P=0.040), sedation (P=0.001), and PaO2/FiO2 (P=0.006) were significantly associated with delirium in univariate analysis. Multivariate regression analysis models were used to further analyze the associations between PaO2/FiO2 and delirium. In the crude model, for 1 standard deviation (SD) increase in PaO2/FiO2, the odds ratio (OR) of delirium was 0.8 (95% confidence interval [CI]: 0.6-0.9), but there was no significant correlation in the fully adjusted model. There was a non-linear relationship between the PaO2/FiO2 and delirium in a generalized additive model. A two-piecewise linear regression model was used to calculate a PaO2/FiO2 threshold of 243 mmHg. On the left side of the threshold, the OR was 0.9 and the 95% CI was 0.9-1.0 (P=0.013) when PaO2/FiO2 increased by 1 SD.

Conclusions: PaO2/FiO2 was negatively associated with delirium when PaO2/FiO2 was below the identified threshold. As a readily available laboratory indicator, PaO2/FiO2 has potential value in the clinical evaluation of risk of delirium in ICU patients.

Keywords: Delirium; Hypoxia; Intensive care unit; Non-linear relationship; Partial pressure of oxygen (PaO2)/Fraction of inspired oxygen (FiO2); Risk factor.