This study aimed to assess the diagnostic performance of the aortic dissection detection risk score (ADD-RS) plus D-dimer for acute aortic syndrome (AAS) in Chinese patients. Two hundred and sixty-two and 200 patients with suspected AAS symptoms were enrolled as exploration cohort and validation cohort, respectively. In exploration cohort, ADD-RS plus D-dimer (AUC = 0.929, 95%CI: 0.887-0.971) presented a better diagnostic value for AAS than ADD-RS or D-dimer alone. Meanwhile, ADD-RS > 1 and D-dimer > 2000 ng/mL were the optimal thresholds. Then, a diagnostic model integrating ADD-RS > 1 plus D-dimer > 2000 ng/mL was established, presenting sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 92.5%, 70.3%, 34.9%, and 98.2%, respectively. In validation cohort, the established diagnostic model exhibited a sensitivity, specificity, PPV, and NPV of 93.1%, 70.2%, 34.6%, and 98.4%, respectively, for diagnosing AAS. Summarily, ADD-RS > 1 and D-dimer > 2000 ng/mL are optimal thresholds for diagnosing AAS in the Chinese population. However, confirmative MSCT results are necessary.
Keywords: Acute aortic syndromes; Aortic dissection detection risk score; D-dimer; Diagnostic model; Optimal threshold.
© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.