Dosimetric parameters and radiotherapy simulation methods used in preclinical studies of radiation damage to the dentition: a systematic review

Oral Surg Oral Med Oral Pathol Oral Radiol. 2023 May;135(5):614-625. doi: 10.1016/j.oooo.2022.12.005. Epub 2022 Dec 23.

Abstract

Objective: This systematic review investigated the dosimetric parameters used in preclinical studies.

Study design: Searches were performed in 3 databases (PubMed, Scopus, and Embase) and gray literature to identify studies for review. In vitro and ex vivo studies that examined the effect of radiation on human permanent teeth were included. The modified Consolidated Standards Of Reporting Trials checklist of items for reporting preclinical in vitro studies was used to assess the risk of bias.

Results: In total, 32 studies met the inclusion criteria. The average radiation dose of in vitro studies was 53 (±22) Gy and in ex vivo studies was 69 (±1) Gy. Twenty-two studies used 5 different fractionation schemes. Twenty-two of the included studies did not report the radiotherapy modality of those reporting. Twenty studies used linear accelerators, and 7 used Cobalt-60 with the source-surface-distance of radiation ranging from 1.5 to 100 cm. Distilled water was the storage solution for the dental structure used most commonly. Biases were observed, including small sample sizes, lack of randomization, and blinding processes.

Conclusion: The dosimetric parameters used in the preclinical studies, including radiation dose, radiotherapy modality, fractionation regime, and the storage solutions used did not support the hypothesis of direct effects of radiation on the dental structure.

Publication types

  • Systematic Review
  • Review
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Checklist*
  • Dentition*
  • Humans