Purpose: To study on the accuracy of implant-borne single restoration by two production processes with Ti-base to provide experimental data for proper processes of single implant-borne restoration.

Methods: Thirty patients were selected with single posterior teeth missing from the Department of Oral Implantology of Shanghai Putuo District Eye Disease and Dental Disease Prevention and Treatment Institute. The patients were taken 2 traditional impressions clinically for two plaster model equipped with implant analogue. These models were then divided into 2 groups according to different production processes. The experimental group was scanned with the scan body installed in the model implant analogue, while the control group was scanned directly on the Ti-base abutment installed in the model implant analogue. The implant-borne single restorations of the two groups were cut along the buccal-lingual side and the distance between the measuring point to the Ti-Base abutment was observed by electron microscopy. In addition, the breaking limit of zirconia crown was observed, universal test machine was used to load direct force to the crown. SPSS 22.0 software package was used for data analysis.

Results: The gap between the implant-borne single restoration to the Ti-base abutment of the experimental group was significantly smaller than that of the control group. The difference between the two groups was statistically significant (P<0.05). However, by testing the breaking limit of zirconia crown, there was no significant difference(P>0.05).

Conclusions: Using scan body to transfer the implant position and Ti-base abutment data information to the digital dental design software is more accurate and reliable than directly scanning the Ti-base on the model analogue. Using scan body is recommended for processing and manufacture of implant-borne singe restoration.

Publication types

  • English Abstract

MeSH terms

  • China
  • Computer-Aided Design
  • Crowns
  • Dental Abutments
  • Dental Implant-Abutment Design*
  • Dental Restoration Failure
  • Dental Stress Analysis
  • Humans
  • Materials Testing
  • Titanium*
  • Zirconium

Substances

  • zirconium oxide
  • Titanium
  • Zirconium