Comparison of Near-Infrared Imaging Agents Targeting the PTPmu Tumor Biomarker

Mol Imaging Biol. 2023 Aug;25(4):744-757. doi: 10.1007/s11307-023-01799-5. Epub 2023 Jan 25.

Abstract

Purpose: Maximal, safe resection of solid tumors is considered a critical first step in successful cancer treatment. The advent of fluorescence image-guided surgery (FIGS) using non-specific agents has improved patient outcomes, particularly in the case of glioblastoma. Molecularly targeted agents that recognize specific tumor biomarkers have the potential to augment these gains. Identification of the optimal combination of targeting moiety and fluorophore is needed prior to initiating clinical trials.

Procedures: A 20-amino acid peptide (SBK2) recognizing the receptor protein-tyrosine phosphatase mu (PTPmu)-derived tumor-specific biomarker, with or without a linker, was conjugated to three different near-infrared fluorophores: indocyanine green (ICG), IRDye® 800CW, and Tide Fluor™ 8WS. The in vivo specificity, time course, and biodistribution were evaluated for each using mice with heterotopic human glioma tumors that express the PTPmu biomarker to identify component combinations with optimal properties for FIGS.

Results: SBK2 conjugated to ICG demonstrated excellent specificity for gliomas in heterotopic tumors. SBK2-ICG showed significantly higher in vivo tumor labeling compared to the Scram-ICG control from 10 min to 24 h, p < 0.01 at all timepoints, following injection, as well as a significantly higher ex vivo tumor signal at 24 h, p < 0.001. Inserting a six-amino acid linker between the targeting peptide and ICG increased the clearance rate and resulted in significantly higher in vivo tumor signal relative to its linker-containing Scrambled control from 10 min to 8 h, p < 0.05 at all timepoints, after dosing. Agents made with the more hydrophilic IRDye® 800CW and Tide Fluor™ 8WS showed no specific tumor labeling relative to the controls. The IRDye 800CW-conjugated agents cleared within 1 h, while the non-specific fluorescent tumor signal generated by the Tide Fluor 8WS-conjugated agents persists beyond 24 h.

Conclusions: The SBK2 PTPmu-targeting peptide conjugated to ICG specifically labels heterotopic human gliomas grown in mice between 10 min and 24 h following injection. Similar molecules constructed with more hydrophilic dyes demonstrated no specificity. These studies present a promising candidate for use in FIGS of PTPmu biomarker-expressing tumors.

Keywords: Astrocytoma; Fluorescence image-guided surgery; Glioblastoma; High-grade glioma; Image-guided resection; Indocyanine green; Molecular imaging; Near-infrared; PTPmu; Receptor protein tyrosine phosphatase.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Amino Acids
  • Animals
  • Biomarkers, Tumor / metabolism
  • Fluorescent Dyes
  • Glioma* / diagnostic imaging
  • Glioma* / drug therapy
  • Humans
  • Indocyanine Green
  • Mice
  • Optical Imaging
  • Phosphoric Monoester Hydrolases
  • Receptor-Like Protein Tyrosine Phosphatases, Class 2* / metabolism
  • Spectroscopy, Near-Infrared / methods
  • Tissue Distribution

Substances

  • Receptor-Like Protein Tyrosine Phosphatases, Class 2
  • Phosphoric Monoester Hydrolases
  • Biomarkers, Tumor
  • Fluorescent Dyes
  • Indocyanine Green
  • Amino Acids