Objective: Endovascular aortic repair (EVAR) with fenestrated (F-EVAR) or branched (B-EVAR) endografts represents an indispensable tool of modern patient care in vascular surgery. The purpose of this retrospective study was to evaluate the center's initial experience of F/B-EVAR procedures performed under biplane angiography guidance compared with a historical control group.

Methods: From January 2020 to March 2022, 80 consecutive patients underwent F/B-EVAR under general anesthesia at a single institution. As from January 2021, the deployment of complex stent grafts was performed using an alternative intraoperative imaging modality-a biplane fluoroscopy and angiography. The cohort was divided into monoplane (MPA) and biplane (BPA) groups according to the imaging modality applied. The end points were operation time, fluoroscopy time, radiation exposure, dose of contrast agent, and technical success.

Results: The MPA group included 59 patients (78% male; median age; 74 years; interquartile range [IQR], 66-78 years) and the BPA group 21 patients (85.7% males; median age, 75 years; IQR, 69-79 years). Operation time (median, 320 minutes; IQR, 266-376 minutes) versus (median, 275 minutes; IQR, 216-333 minutes) was significantly lower in the BPA group (P = .006). The median fluoroscopy time (median, 82 minutes; IQR, 57-110 minutes vs median, 68 minutes; IQR, 54-92 minutes), contrast agent volume applied (median, 220 mL; IQR, 179-250 mL vs median, 200 mL; IQR, 170-250 mL), and radiation dose (dose-area product, median, 413 Gy × cm2; IQR, 249-736 Gy × cm2; vs median, 542 Gy × cm2; IQR, 196-789 Gy × cm2) were similar in both groups. Technical success of 96.6% (57/59 cases) versus 100% (21/21 cases) could be achieved in MPA and BPA group, respectively.

Conclusions: F/B-EVAR procedures performed under BPA guidance were associated with a significant decrease in operation time.

Keywords: Biplane angiography; Endovascular procedures; Monoplane angiography.

MeSH terms

  • Aged
  • Aortic Aneurysm, Abdominal* / surgery
  • Aortography / adverse effects
  • Aortography / methods
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / methods
  • Contrast Media
  • Endovascular Aneurysm Repair
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / methods
  • Female
  • Fluoroscopy
  • Humans
  • Male
  • Radiation Dosage
  • Retrospective Studies
  • Treatment Outcome

Substances

  • Contrast Media