Clinical and radiographic outcomes following anatomic total shoulder arthroplasty utilizing an inset glenoid component at 2-year minimum follow-up: a dual center study

J Shoulder Elbow Surg. 2023 Jun;32(6):1222-1230. doi: 10.1016/j.jse.2022.11.021. Epub 2022 Dec 28.

Abstract

Background: Anatomic total shoulder arthroplasty (aTSA) is a successful and reproducible treatment for patients with painful glenohumeral arthritis. However, long-term outcomes using traditional onlay glenoid components have been tempered by glenoid loosening. Inset components have been proposed to minimize glenoid loosening by reducing edge-loading and opposite-edge lift-off forces with humeral translation. Successful short- and long-term outcomes have been reported while using inset glenoid implants. The current study is the largest study presenting a minimum of 2-year follow-up data following aTSA with an all-polyethylene inset glenoid component (Shoulder Innovations, Holland, MI, USA).

Methods: A dual center, retrospective review of patients undergoing aTSA using an Inset glenoid component by 2 fellowship-trained shoulder surgeons at 2 separate institutions from August, 2016, to August, 2019, was performed. Minimum follow-up was 2 years. Range of motion (ROM), visual analog scale (VAS) pain scores, Single Assessment Numeric Evaluation (SANE), and American Shoulder and Elbow Surgeons (ASES) scores were obtained. Radiographic outcomes, including central peg lucency and glenoid loosening, were assessed by 3 independent reviewers on the postoperative Grashey and axillary radiographs obtained at the final follow-up.

Results: Seventy-five shoulders were included for the final analysis. The mean age of the entire cohort was 64 (±11.4) years. Twenty-one (28%) glenoids were type A1, 10 (13.3%) were type A2, 13 (17.3%) were type B1, 22 (29.3%) were type B2, 6 (8%) were type B3, and 3 (4%) were type D. At a minimum follow-up of 24 months (mean: 28.7 months), a significant improvement in ROM in all planes was observed. Significant improvements in VAS (5.1-0.9, P < .001), SANE (39.5-91.2, P < .001), and ASES (43.7-86.6, P < .001) scores were observed. There were 4 (5.3%) cases of central peg lucency about the inset glenoid component and one (1.3%) case of glenoid loosening. No revisions were performed for glenoid loosening.

Conclusion: At a minimum of 2 years postoperatively, there were significant improvements in ROM, VAS, SANE, and ASES scores with very low rates of central peg lucency and glenoid loosening in patients undergoing aTSA with an inset glenoid component. Further work is needed to determine the long-term benefit of this novel implant.

Keywords: Inset glenoid; anatomic total shoulder arthroplasty; central peg lucency; glenohumeral arthritis; glenoid loosening; patient-reported outcome measures.

MeSH terms

  • Aged
  • Arthroplasty, Replacement, Shoulder*
  • Follow-Up Studies
  • Glenoid Cavity* / surgery
  • Humans
  • Middle Aged
  • Prosthesis Design
  • Range of Motion, Articular
  • Retrospective Studies
  • Scapula / surgery
  • Shoulder Joint* / diagnostic imaging
  • Shoulder Joint* / surgery
  • Shoulder Prosthesis*
  • Treatment Outcome