Combined Effect of Ultrasound and Low-Heat Treatments on E. coli in Liquid Egg Products and Analysis of the Inducted Structural Alterations by NIR Spectroscopy

Sensors (Basel). 2022 Dec 16;22(24):9941. doi: 10.3390/s22249941.

Abstract

In this study, sonication with mild heat treatment was used to reduce the E. coli count in inoculated liquid whole egg, egg yolk and albumen. Ultrasonic equipment (20/40 kHz, 180/300 W) has been used for 30/60 min with a 55 °C water bath. The combination of sonication and low-heat treatment was able to reduce the concentration of E. coli from 5-log CFU × mL-1 below 10 CFU × mL-1 at 300 W, 40 kHz and 60 min of sonication in liquid egg products. The 60 min treatment was able to reduce the E. coli concentration below 10 CFU × mL-1 in the case of egg yolk regardless of the applied frequency, absorbed power or applied energy dose. The 30 min treatment of sonication and heating was able to reduce significantly the number of E. coli in the egg products, as well. Our results showed that sonication with mild heat treatment can be a useful technique to decrease the number of microorganisms in liquid egg products to a very low level. Near-infrared spectroscopy was used to investigate structural changes in the samples, induced by the combined treatment. Principal component analysis showed that this method can alter the C-H, C-N, -OH and -NH bonds in these egg products.

Keywords: albumen; egg; preservation; quality; ultrasonic; yolk.

MeSH terms

  • Colony Count, Microbial
  • Eggs / analysis
  • Escherichia coli*
  • Hot Temperature
  • Spectroscopy, Near-Infrared*