Dual-energy computed tomography iodine uptake in differential diagnosis of inflammatory and malignant pulmonary nodules

Diagn Interv Radiol. 2022 Nov;28(6):563-568. doi: 10.5152/dir.2022.201091.

Abstract

PURPOSE The aim of this study was to evaluate the diagnostic performance of iodine uptake parameters using dual-energy computed tomography (DECT) in discriminating inflammatory nodules from malignant tumors. METHODS This retrospective study included 116 solid pulmonary nodules from 112 patients who were admitted to our hospital between January and September 2018. All nodules were confirmed by surgery or puncture. The degree of enhancement of a single-section region of interest was evalu ated. After total tumor volume-of-interest segmentation, the mean iodine density of the whole tumor was measured. Meanwhile, iodine uptake parameters, including total iodine uptake vol ume, total iodine concentration, vital iodine uptake volume, and vital iodine concentration, were calculated, and a predictive model was established. The overall ability to discriminate between inflammatory and malignant nodules was analyzed using an independent samples t-test for normally distributed variables. The diagnostic accuracy and prognostic performance of DECT parameters were evaluated and compared using receiver operating characteristic curve analysis and logistic regression analysis. A multivariate logistic regression analysis was used to determine the prognostic factors and goodness-of-fit of the whole tumor mean iodine and iodine uptake parameters for discriminating malignant nodules. RESULTS There were 116 non-calcified nodules, including 64 inflammatory nodules and 52 malignant nodules. The degree of enhancement in malignant nodules was significantly lower than that in inflammatory nodules (P=.043). All iodine uptake parameters in malignant nodules were signifi cantly higher than those in inflammatory nodules (P < .001). The area under the receiver operat ing curve value, accuracy, sensitivity, and specificity of the established model based on iodine uptake parameters were 0.803, 76.72%, 82.69%, and 84.37%, respectively, which exhibited bet ter diagnostic performance than the degree of enhancement on weighted average images with respective values of 0.609, 59.48%, 61.54%, and 59.38%. CONCLUSION The iodine uptake parameters of DECT exhibited better diagnostic accuracy in discriminating inflammatory nodules from malignant nodules than the degree of enhancement on weighted average images.

MeSH terms

  • Contrast Media
  • Diagnosis, Differential
  • Humans
  • Iodine*
  • Multiple Pulmonary Nodules* / diagnostic imaging
  • Retrospective Studies
  • Tomography, X-Ray Computed / methods

Substances

  • Iodine
  • Contrast Media