Printable Graphene-Sustainable Elastomer-Based Cross Talk Free Sensor for Point of Care Diagnostics

ACS Appl Mater Interfaces. 2022 Dec 28;14(51):57265-57280. doi: 10.1021/acsami.2c17805. Epub 2022 Dec 15.

Abstract

Developing sensors for monitoring physiological parameters such as temperature and strain for point of care (POC) diagnostics is critical for better care of the patients. Various commercial sensors are available to get the job done; however, challenges like the structural rigidity of such sensors confine their usage. As an alternative, flexible sensors have been looked upon recently. In most cases, flexible sensors cannot discriminate the signals from different stimuli. While there have been reports on the printable sensors providing cross-talk-free solutions, research related to developing sensors from a sustainable source providing discriminability between signals is not well-explored. Herein, we report the development of a stencil printable composition made of graphene and epoxidized natural rubber. The stencil printability index was vetted using rheological studies. Post usage, the developed sensor was dissolved in an organic solvent at room temperature. This, along with the choice of a sustainable elastomer, warrants the minimization of electronic waste and carbon footprint. The developed material demonstrated good conformability with the skin and could perceive and decouple the signals from temperature and strain without inducing any crosstalks. Using a representative volume element model, a comparison between experimental findings and computation studies was made. The developed sensors demonstrated gauge factors of -506 and 407 in the bending strain regimes of 0-0.04% and 0.04%-0.09%, respectively, while the temperature sensitivity was noted to be -0.96%/°C. The printed sensors demonstrated a multifunctional sensing behavior for monitoring various active physiological parameters ranging from temperature, strain, pulse, and breathing to auditory responses. Using a Bluetooth module, various parameters like temperature and strain could be monitored seamlessly in a smart-phone. The current development would be crucial to open new avenues to fabricate crosstalk-free sensors from sustainable sources for POC diagnostics.

Keywords: flexible electronics; graphene; multifunctional sensor; real-time monitoring; stencil printing; sustainable elastomer; wearable electronics.

MeSH terms

  • Elastomers / chemistry
  • Graphite*
  • Humans
  • Point-of-Care Testing
  • Temperature
  • Wearable Electronic Devices*

Substances

  • Graphite
  • Elastomers