Relationship of 24-h ambulatory blood pressure variability with micro and macrovascular parameters and hypertension status

J Hypertens. 2023 Jan 1;41(1):74-82. doi: 10.1097/HJH.0000000000003300. Epub 2022 Oct 4.

Abstract

Objectives: Increased blood pressure variability (BPV) has been associated with an increased risk of subclinical organ damage and cardiovascular events, independently of elevated average BP values. We aimed to investigate the association of BPV indices with micro- and macrovascular parameters, some of them not previously studied.

Methods: We evaluated 344 individuals (233 never-treated/newly diagnosed hypertensive and 111 normotensive individuals). BPV was assessed using average real variability (ARV) during 24-h, daytime and night-time ambulatory blood pressure monitoring, and systolic weighted standard deviation (wSD). Retinal microvascular diameter was assessed by nonmydriatic retinal photography. Arterial stiffness was assessed by pulse wave velocity (PWV) and aortic augmentation index (AIx); subendocardial variability ratio (SEVR) was used as an index of myocardial perfusion. Carotid intima-media thickness (cIMT) was measured by ultrasound. Data were analyzed using multiple regression analysis.

Results: After adjusting for potential confounders, PWV and cIMT were independently associated with ARV components in the total sample (P < 0.023 and P < 0.014, respectively). Within hypertensives only PWV and cIMT were independently associated with ARV components (P < 0.002 for PWV and P < 0.003 for cIMT). In contrast, within normotensives, only retinal parameters and AIx were associated with ARV components (P < 0.017 and P = 0.013, respectively). None of the univariate correlations between vascular parameters and wSD remained significant after adjustment for potential confounders.

Conclusion: Short-term BPV as assessed by ARV is independently associated with macrovascular parameters in untreated hypertensive patients, and with microvascular parameters in normotensive individuals.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Blood Pressure
  • Blood Pressure Monitoring, Ambulatory
  • Carotid Intima-Media Thickness
  • Female
  • Humans
  • Hypertension*
  • Pregnancy
  • Pulse Wave Analysis*