Use of dual-mobility cup in primary total hip arthroplasties: an Italian regional register (RIPO) study on three thousand, seven hundred and ten cases

Int Orthop. 2023 Jan;47(1):99-106. doi: 10.1007/s00264-022-05639-z. Epub 2022 Nov 30.

Abstract

Purpose: The purpose of the study was to investigate the outcome of dual-mobility cup (DM) compared with a standard cup (SC) in primary total hip arthroplasty (THA) in the long-term follow-up based on a regional Italian joint registry (RIPO).

Methods: The Registry of Prosthetic Orthopaedic Implant (RIPO) was consulted, looking for all primary THAs implanted from 2000 to 2019. Three thousand seven hundred ten were dual-mobility cup (DM) total hip arthroplasties (THA) and 85.816 were standard cup (SC) THAs, on a total of 89.526 primary THA. Demographics, survival rates and causes of revision were evaluated and compared between the two groups.

Results: The use of DM progressively increased from 0.4% in 2000 to 7.5% in 2018 of all primary THAs. Revision rate was 3.5% (128 on 3710) for DMC and 4.7% (4061 on 85,816) for SC. DM presented lower dislocation rate if compared to SC with 22-28-mm femoral head diameter. However, DM showed a higher risk of revision for any causes than SC with 32-mm femoral head diameter in long-term follow-up. Nevertheless, no significant difference was measured in terms of demographics and surgical approach for dislocation rate.

Conclusions: The DM cup represents a valid implant solution and has a lower dislocation rate than 22-28-mm SC. A slight increase in the use of DM implants over time was observed in the RIPO. However, a larger population and a longer follow-up are needed to further monitor the survival rate of new-generation DM implants.

Keywords: Aseptic loosening; Dislocation; Dual-mobility cup; Intraprosthetic dislocation; Standard cup; Total hip arthroplasty.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Arthroplasty, Replacement, Hip* / adverse effects
  • Follow-Up Studies
  • Hip Dislocation* / surgery
  • Hip Prosthesis* / adverse effects
  • Humans
  • Joint Dislocations* / surgery
  • Orthopedics*
  • Prosthesis Design
  • Prosthesis Failure
  • Registries
  • Reoperation / adverse effects
  • Retrospective Studies