Development of a mid-infrared sensor system for early fire identification in cotton harvesting operations

Analyst. 2022 Dec 20;148(1):74-84. doi: 10.1039/d2an01523d.

Abstract

To realize early fire identification in cotton harvesting operations, a mid-infrared carbon monoxide (CO) sensor system was developed. To match the broadband light source with a 15° divergence angle, a multipass gas cell (MPGC) with an effective path length of 180 cm was designed to improve sensor sensitivity, leading to a limit of detection (LoD) of 0.83 parts-per-million by volume (ppmv). A damping module with springs at the bottom and front/back sides was fabricated, which can effectively reduce the vibration intensity by >80%. The sensor system can operate normally from -40 °C to 85 °C by stabilizing the temperature of the optical module through heating or cooling as well as using automotive electronic components. An adaptive early fire identification algorithm based on a dual-parameter threshold alarming method was proposed to avoid false and missing alarms. Field deployments on a harvester verified the good practicability of the sensor system.

MeSH terms

  • Carbon Monoxide*
  • Cold Temperature*
  • Limit of Detection
  • Temperature

Substances

  • Carbon Monoxide