Usefulness of Intraoperative Electrocorticography for the Localization of Epileptogenic Zones

Neurol Med Chir (Tokyo). 2023 Feb 15;63(2):65-72. doi: 10.2176/jns-nmc.2022-0252. Epub 2022 Nov 25.

Abstract

Intraoperative electrocorticography (iECoG) is widely performed to identify irritative zones in the cortex during brain surgery; however, several limitations (e.g., short recording times and the effects of general anesthesia) reduce its effectiveness. The present study aimed to evaluate the utility of iECoG for localizing epileptogenic zones. We compared the results of iECoG and chronic electrocorticography (cECoG) in 25 patients with refractory epilepsy. Subdural electrodes were implanted with iECoG under general anesthesia (2% sevoflurane). cECoG recordings were performed for 3-14 days. The distribution of iECoG spikes was compared with cECoG spike, seizure onset zone, and resection areas. The concordance patterns of each distribution were classified into four patterns: Group 1: No spike in iECoG, Group 2: concordant (2a: iECoG smaller, 2b: iECoG larger, Group 3: discordant >50%). The concordance rate of interictal spikes, seizure onset zones, and resection areas were 88.0% (Group 2a: 72.0%, Group 2b: 16.0%), 70.0% (Group 2a: 25.0%, Group 2b: 45.0%), and 81.0% (Group 2a: 42.9%, Group 2b: 38.1%), respectively. The resection of iECoG spike areas significantly correlated with good surgical outcomes. The indication and limitations of iECoG need to be realized, and the complementary use of iECoG and cECoG may enhance clinical utility.

Keywords: anesthesia; intracranial electrode; intraoperative electrocorticography; invasive evaluation.

MeSH terms

  • Anesthesia, General
  • Cerebral Cortex
  • Drug Resistant Epilepsy* / diagnosis
  • Drug Resistant Epilepsy* / surgery
  • Electrocorticography*
  • Electroencephalography
  • Humans
  • Seizures