Four-Dimensional Computed Tomography Ventilation Image-Guided Lung Functional Avoidance Radiation Therapy: A Single-Arm Prospective Pilot Clinical Trial

Int J Radiat Oncol Biol Phys. 2023 Apr 1;115(5):1144-1154. doi: 10.1016/j.ijrobp.2022.11.026. Epub 2022 Nov 24.

Abstract

Purpose: The primary objective of this prospective pilot trial was to assess the safety and feasibility of lung functional avoidance radiation therapy (RT) with 4-dimensional (4D) computed tomography (CT) ventilation imaging.

Methods and materials: Patients with primary lung cancer or metastatic disease to the lungs to receive conventionally fractionated RT (CFRT) or stereotactic body RT (SBRT) were eligible. Standard-of-care 4D-CT scans were used to generate ventilation images through image processing/analysis. Each patient required a standard intensity modulated RT plan and ventilation image guided functional avoidance plan. The primary endpoint was the safety of functional avoidance RT, defined as the rate of grade ≥3 adverse events (AEs) that occurred ≤12 months after treatment. Protocol treatment was considered safe if the rates of grade ≥3 pneumonitis and esophagitis were <13% and <21%, respectively for CFRT, and if the rate of any grade ≥3 AEs was <28% for SBRT. Feasibility of functional avoidance RT was assessed by comparison of dose metrics between the 2 plans using the Wilcoxon signed-rank test.

Results: Between May 2015 and November 2019, 34 patients with non-small cell lung cancer were enrolled, and 33 patients were evaluable (n = 24 for CFRT; n = 9 for SBRT). Median follow-up was 14.7 months. For CFRT, the rates of grade ≥3 pneumonitis and esophagitis were 4.2% (95% confidence interval, 0.1%-21.1%) and 12.5% (2.7%-32.4%). For SBRT, no patients developed grade ≥3 AEs. Compared with the standard plans, the functional avoidance plans significantly (P < .01) reduced the lung dose-function metrics without compromising target coverage or adherence to standard organs at risk constraints.

Conclusions: This study, representing one of the first prospective investigations on lung functional avoidance RT, demonstrated that the 4D-CT ventilation image guided functional avoidance RT that significantly reduced dose to ventilated lung regions could be safely administered, adding to the growing body of evidence for its clinical utility.

Publication types

  • Clinical Trial
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Carcinoma, Non-Small-Cell Lung* / diagnostic imaging
  • Carcinoma, Non-Small-Cell Lung* / pathology
  • Carcinoma, Non-Small-Cell Lung* / radiotherapy
  • Four-Dimensional Computed Tomography / methods
  • Humans
  • Lung / pathology
  • Lung Neoplasms* / diagnostic imaging
  • Lung Neoplasms* / pathology
  • Lung Neoplasms* / radiotherapy
  • Prospective Studies
  • Radiotherapy Planning, Computer-Assisted / methods