Influencing factors of the thermal environment of urban green space

Heliyon. 2022 Nov 12;8(11):e11559. doi: 10.1016/j.heliyon.2022.e11559. eCollection 2022 Nov.

Abstract

Several heat records have been broken in recent years and decades. Extreme high temperature not only damages human health, but also increases the risk of wildfires. As a common urban infrastructure, urban green space has been proved to have a cooling effect. In this study, the physical indicators and temperature data of 36 green spaces in Xi'an were collected, and the influence of different physical indicators of green spaces on their thermal environment was explored through correlation analysis. The results suggest that the area of green space should be between 0.6-0.7 square kilometers or the perimeter should range from 4000 to 4500 m in order to obtain the lowest internal temperature. When the area of water body in the green space is between 0.3-0.4 square kilometers or the perimeter is about 5000 m, its internal temperature is the lowest. Indicators of green space in the conclusion can be directly understood and referred by urban planners and policy makers. Results of this study thus have implications for improving urban thermal comfort by controlling the physical indicators of green space.

Keywords: Cooling effect; Fixed effect model; Remote sensing; Urban green space.