Survival and complications of zygomatic implants compared to conventional implants reported in longitudinal studies with a follow-up period of at least 5 years: A systematic review and meta-analysis

Clin Implant Dent Relat Res. 2023 Feb;25(1):177-189. doi: 10.1111/cid.13153. Epub 2022 Nov 14.

Abstract

Background: Zygomatic implants (ZI) have been frequently indicated to rehabilitate patients with extensive atrophies in alternatives to major bone reconstructions. It can be installed inside the maxillary sinus, called instrasinus zygomatic implant (IZI) or outside the maxillary sinus (EZI), depending on the surgery technique.

Objective: To evaluate the survival and complication rates of ZI in longitudinal studies when compared with conventional implants (CI).

Methods: An electronic search was performed in five databases and in Gray literature for articles published until April, 2022. The eligibility criteria comprised observational cohort studies (prospective or retrospective) and randomized clinical trials (RCTs) with at least 5 years of follow-up, reporting survival rate of ZI versus CI. A meta-analysis was conduct with 18 studies.

Results: A total of 5434 implants (2972 ZI and 2462 CI) were analyzed in 1709 patients. The mean survival rate was 96.5% ± 5.02 and 95.8% ± 6.36 for ZI and CI, respectively (mean follow-up time of 78 months). There were observed no statistically significant between ZI and CI in prospective studies (risk ratio [RR] of 1.21; 95% confidence intervals [CIs]: 0.28 to 5.28; chi-squared [Chi2 ] = 11.37; I2 = 56%; degrees of freedom [df] = 5; z-score = 0.25; P = 0.80), retrospective studies IZI (RR of 1.29; 95% CIs: 0.52 to 3.23; Chi2 = 4.07; I2 = 2%; df = 4; z-score = 0.55; P = 0.58) and retrospective studies EZI (RR of 0.72; 95% CIs: 0.31 to 1.66; Chi2 = 1.99; I2 = 0%; df = 3; z-score = 0.78; P = 0.44). The biological complications most related to ZI was sinusitis, followed by infection and oroantral communication.

Conclusion: ZI have a high long-term survival rate (96.5% with a mean of 91.5 months of follow-up), showing no significant difference when compared with CI. The most prevalent biological complication is sinusitis, being most commonly to the IZI technique. This systematic review (SR) was registered in INPLASY under number INPLASY202280025.

Keywords: complications; survival rate; systematic review; zygomatic implants.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Dental Implantation, Endosseous / adverse effects
  • Dental Implantation, Endosseous / methods
  • Dental Implants* / adverse effects
  • Dental Prosthesis, Implant-Supported
  • Follow-Up Studies
  • Humans
  • Longitudinal Studies
  • Maxilla / surgery
  • Sinusitis* / surgery
  • Zygoma / surgery

Substances

  • Dental Implants