Efficacy and Damage Diagnosis of Reinforced Concrete Columns and Joints Strengthened with FRP Ropes Using Piezoelectric Transducers

Sensors (Basel). 2022 Oct 29;22(21):8294. doi: 10.3390/s22218294.

Abstract

Recent research has indicated that the implantation of a network of piezoelectric transducer patches in element regions of potential damage development, such as the beam-column joint (BCJ) area, substantially increases the efficacy and accuracy of the structural health monitoring (SHM) methods to identify damage level, providing a reliable diagnosis. The use of piezoelectric lead zirconate titanate (PZT) transducers for the examination of the efficiency of an innovative strengthening technique of reinforced concrete (RC) columns and BCJs is presented and commented on. Two real-scale RC BCJ subassemblages were constructed for this investigation. The columns and the joint panel of the second subassemblage were externally strengthened with carbon fiber-reinforced polymer (C-FRP) ropes. To examine the efficiency of this strengthening technique we used the following transducers: (a) PZT sensors on the ropes and the concrete; (b) tSring linear variable displacement transducers (SLVDTs), diagonally installed on the BCJ, to measure the shear deformations of the BCJ panel; (c) Strain gauges on the internal steel bars. From the experimental results, it became apparent that the PZT transducers successfully diagnosed the loading step at which the primary damage occurred in the first BCJ subassemblage and the damage state of the strengthened BCJ during the loading procedure. Further, data acquired from the diagonal SLVDTs and the strain gauges provided insight into the damage state of the two tested specimens at each step of the loading procedure and confirmed the diagnosis provided by the PZT transducers. Furthermore, data acquired by the PZT transducers, SLVDTs and strain gauges proved the effectiveness of the applied strengthening technique with C-FRP ropes externally mounted on the column and the conjunction area of the examined BCJ subassemblages.

Keywords: beam-column joint (BCJ); carbon fiber-reinforced polymer (C-FRP) ropes; piezoelectric lead zirconate titanate (PZT) transducers; real-scale tests; reinforced concrete (RC); string linear variable displacement transducers (SLVDTs); structural health monitoring (SHM).

MeSH terms

  • Polymers / chemistry
  • Titanium / chemistry
  • Transducers*
  • Zirconium* / chemistry

Substances

  • lead titanate zirconate
  • Zirconium
  • Titanium
  • Polymers