Pharmacokinetic Characteristics of Nebulized Colistimethate Sodium Using Two Different Types of Nebulizers in Critically Ill Patients with Ventilator-Associated Respiratory Infections

Antibiotics (Basel). 2022 Nov 1;11(11):1528. doi: 10.3390/antibiotics11111528.

Abstract

Background: Rising antimicrobial resistance has led to a revived interest in inhaled colistin treatment in the critically ill patient with ventilator-associated respiratory infection (VARI). Nebulization via vibrating mesh nebulizers (VMNs) is considered the current standard-of-care, yet the use of generic jet nebulizers (JNs) is more widespread. Few data exist on the intrapulmonary pharmacokinetics of colistin when administered through VMNs, while there is a complete paucity regarding the use of JNs. Methods: In this study, 18 VARI patients who received 2 million international units of inhaled colistimethate sodium (CMS) through a VMN were pharmacokinetically compared with six VARI patients who received the same drug dose through a JN, in the absence of systemic CMS administration. Results: Surprisingly, VMN and JN led to comparable formed colistin exposures in the epithelial lining fluid (ELF) (median (IQR) AUC0-24: 86.2 (46.0-185.9) mg/L∙h with VMN and 91.5 (78.1-110.3) mg/L∙h with JN). The maximum ELF concentration was 10.4 (4.7-22.6) mg/L and 7.4 (6.2-10.3) mg/L, respectively. Conclusions: Based on our results, JN might be considered a viable alternative to the theoretically superior VMN. Therapeutic drug monitoring in the ELF can be advised due to the observed low exposure, high variability, and appreciable systemic absorption.

Keywords: ELF colistin concentration; colistin pharmacokinetics; critically ill; inhaled colistin; jet nebulizer; vibrating mesh nebulizer.