Anatomic reconstruction of the lateral ligaments using allograft tendon and suspensory fixation for chronic lateral ankle instability with poor remnant quality: results and complications

Arch Orthop Trauma Surg. 2023 Jun;143(6):3231-3237. doi: 10.1007/s00402-022-04680-2. Epub 2022 Nov 5.

Abstract

Purpose: Treatment of chronic lateral ankle instability (CLAI) with poor remnant quality is challenging. The aim of the present study was to evaluate clinical results and complications of anatomic reconstruction of the lateral ligaments using allograft tendon and suspensory fixation in the treatment of such patients.

Methods: One hundred and eight patients with CLAI, who were treated surgically using anatomic reconstruction with allograft tendon and suspensory fixation between April 2016 and January 2018 at our hospital, were retrospectively analysed. None of the patients had sufficient ligament remnants for the modified Broström procedure during the intraoperative evaluation. Eighteen patients were excluded. Seventeen patients were lost to follow-up and 73 patients completed the study. The mean duration of instability symptoms was 39.1 months (range, 6-480 months). The mean follow-up time was 57.5 months (range, 48-69 months). Clinical results were evaluated using the Karlsson scoring scale, American Orthopaedic Foot and Ankle Society-Ankle and Hindfoot (AOFAS-AH) score, visual analogue scale (VAS), patients' subjective satisfaction, and incidence of complications. Mechanical stability was evaluated using the varus talar tilt angle (TTA) and anterior talar displacement (ATD).

Results: The AOFAS-AH scores significantly improved from 67.7 ± 8.5 points to 89.8 ± 9.5 (p < 0.001). The Karlsson scoring scales evolved from 58.8 ± 16.5 to 88.4 ± 11.2 (p < 0.001). VAS scores significantly decreased from 2.9 ± 1.3 to 1.1 ± 1.0 (p < 0.001). On stress radiographs, TTA decreased from 15.1 ± 2.5 degrees to 5.8 ± 2.1 degrees (p < 0.001), whereas ATD reduced from 13.4 ± 2.9 mm to 5.7 ± 1.5 mm (p < 0.001). Patients' subjective satisfaction indicated 46 excellent, 20 good, 5 fair, and 2 bad results. Postoperatively, 15 cases (20.5%) did not achieve complete relief of discomfort or swelling, 9 cases (12.3%) experienced joint stiffness or decreased range of motion, and 6 cases (8.2%) had soft tissue irritation. Residual instability and reoperation are rare. Allograft rejection or wound infection was not observed.

Conclusion: For the CLAI patients with poor remnant quality, anatomic reconstruction of the lateral ligaments using allograft tendon and suspensory fixation is an effective procedure, while the top three complications in incidence were residual discomfort, joint stiffness, and soft tissue irritation.

Levels of evidence: Level IV, retrospective case series.

Keywords: Allograft; Anatomic reconstruction; Chronic lateral ankle instability; Clinical result; Complication; Suspensory fixation.

MeSH terms

  • Allografts
  • Ankle
  • Ankle Joint / surgery
  • Humans
  • Joint Instability* / diagnosis
  • Joint Instability* / surgery
  • Lateral Ligament, Ankle* / surgery
  • Retrospective Studies
  • Tendons / transplantation