HPV Tests Comparison in the Detection and Follow-Up after Surgical Treatment of CIN2+ Lesions

Diagnostics (Basel). 2022 Sep 29;12(10):2359. doi: 10.3390/diagnostics12102359.

Abstract

Background: HPV tests differ for technology, targets, and information on genotyping of high risk (HR) HPV. In this study, we evaluated the performance of 6 HPV DNA tests and one mRNA test in the detection of cervical intraepithelial lesions (CIN) and as a test-of-cure in the follow-up after surgical conservative treatment.

Methods: One hundred seventy-two women referred to the European Institute of Oncology, Milan, for surgical treatment of pre-neoplastic cervical lesions, were enrolled in this study (IEO S544) from January 2011 to June 2015. For all women, a cervical sample was taken before treatment (baseline) and at the first follow-up visit (range 3 to 9 months): on these samples Qiagen Hybrid Capture 2 (HC2), Roche Linear Array HPV Test (Linear Array), Roche Cobas 4800 HPV test (Cobas), Abbott RealTime High Risk HPV test (RT), BD Onclarity HPV assay (Onclarity), Seegene Anyplex II HPV HR Detection (Anyplex), and Hologic Aptima HPV Assay (Aptima) histology and cytology were performed at baseline, and the same tests and cytology were performed at follow-up.

Results: At baseline 158/172 (92%), histologies were CIN2+, and 150/172 (87%) women were recruited at follow-up. Assuming HC2 as a comparator, the concordance of HPV tests ranges from 91% to 95% at baseline and from 76% to 100% at follow-up (PABAK ranging from 0.81 to 0.90 at baseline and PABAK ranging from 0.53 to 1 at follow-up). All HPV showed a very good sensitivity in CIN2+ detection at baseline, more than 92%, and a very good specificity at follow-up, more than 89%.

Conclusions: HPV tests showed a good concordance with HC2 and a very good and comparable sensitivity in CIN2+ detection. Hence, an HPV test represents a valid option as test-of-cure in order to monitor patients treated for CIN2+ lesions during follow-up.

Keywords: HPV; cervical intraepithelial neoplasia; concordance; follow-up; genotyping; real time PCR.

Grants and funding

The funding for this study was provided by HPV test companies that supplied free kits for the assays. The Funder had the right to read and comment upon the manuscript, but without editorial rights, nor any role in the final interpretation of the data.