Identifying robust and reliable volatile organic compounds in human sebum for biomarker discovery

Anal Chim Acta. 2022 Nov 15:1233:340506. doi: 10.1016/j.aca.2022.340506. Epub 2022 Oct 12.

Abstract

Sebum from sebaceous glands is a rich source of volatile organic compounds (VOCs) that can readily be sampled non-invasively from the surface of skin. The VOC profiles of sebum can then be used to obtain information regarding different medical conditions including diabetes and Parkinson's Disease. However, the effects of sampling approaches and environmental factors on sebum VOC profiles are not established and the confident attribution of VOCs to disease states needs to be free of extraneous influences such as sampling materials and preparatory conditions. Here, we investigated a more standardised skin swab sampling approach for profiling sebum VOCs from healthy human subjects using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Using a standard GC-MS method for the chemical analysis of sebum swabs, a surprisingly high number of VOCs originate from 'blank' medical swab material alone (up to 74 VOCs) and from the ambient environment (up to 29 VOCs) based on control experiments. We found that heat-treatment of medical swabs prior to GC-MS reduced the number of VOCs detected from 'blank' swabs and improved the reproducibility of VOC profiling, however significant VOC absorption can still occur from environmental exposure to ambient air. VOCs identified in 'blank' swabs consisted predominantly of hydrocarbons, esters, and silicon-based compounds and depended strongly on the material used (cotton and polyester-rayon). Environmental VOCs found to absorb to swabs from the ambient air during sampling included 1-butylheptyl-benzene and hexadecanoic acid methyl ester as well as exogenous VOCs such as isopropyl palmitate and isopropyl myristate. In contrast, sebum VOCs consisted primarily of esters, alcohols, ketones, and aldehydes. 23 and 18 VOCs were identified in sebum collected using polyester-rayon and cotton-based medical swabs, respectively, with 14 VOCs common to both swabs. The effect of subject bathing prior to sebum sampling had minimal impact on the VOC profiles. However, individual differences owing to external factors such as skin type, diet, and exercise will likely influence sebum production. This study highlights the importance of using rigorous controls in sebum sampling, and recommendations are provided for future research involving sebum VOC analysis. For example, the use of sebum sample replicates across multiple days, and the use of control swabs during sample collection is required to confirm the origin and reliability of sebum VOCs. It is anticipated that these recommendations in conjunction with a library of well-established VOCs from medical swabs will further strengthen biomarker identification resulting from sebum VOC analysis.

MeSH terms

  • Air Pollutants* / analysis
  • Aldehydes / analysis
  • Benzene
  • Biomarkers / analysis
  • Environmental Monitoring / methods
  • Esters / analysis
  • Gas Chromatography-Mass Spectrometry
  • Humans
  • Hydrocarbons
  • Ketones / analysis
  • Palmitic Acid
  • Polyesters
  • Reproducibility of Results
  • Sebum / chemistry
  • Silicon
  • Volatile Organic Compounds* / analysis

Substances

  • Volatile Organic Compounds
  • Air Pollutants
  • Benzene
  • Palmitic Acid
  • Silicon
  • Hydrocarbons
  • Aldehydes
  • Biomarkers
  • Esters
  • Ketones
  • Polyesters