Single-shot blind deconvolution with coded aperture

Appl Opt. 2022 Aug 1;61(22):6408-6413. doi: 10.1364/AO.460763.

Abstract

In this paper, we present a method for single-shot blind deconvolution incorporating a coded aperture (CA). In this method, we utilize the CA, inserted on the pupil plane, as support constraints in blind deconvolution. Not only an object is estimated, but also a point spread function of turbulence from a single captured image by a reconstruction algorithm with CA support. The proposed method is demonstrated by simulation and an experiment in which point sources are recovered under severe turbulence.