Repair of coronary artery ostium with a ring-shaped bovine pericardial patch

Interact Cardiovasc Thorac Surg. 2022 Oct 10;35(5):ivac251. doi: 10.1093/icvts/ivac251.

Abstract

As an approach to coronary artery ostial injury in type A aortic dissection and infective endocarditis, we describe a technique of coronary ostial repair using a ring-shaped bovine pericardial patch. The inner and outer rims of the patch were sutured to the involved coronary ostium (to close the ostial tear) and to the aortic wall (to cover the sinus), respectively. Four patients were successfully managed and computed tomographic coronary arteriogram at follow-up showed patent coronary ostia and arteries. The favourable preliminary results imply that this technique is a simple, safe and effective approach to coronary ostial repair in patients with type A aortic dissection or infective endocarditis.

Keywords: Aortic dissection; Bovine pericardial patch; Coronary artery/ostium; Endocarditis; Surgical outcomes.

MeSH terms

  • Animals
  • Aortic Dissection* / diagnostic imaging
  • Aortic Dissection* / surgery
  • Cardiac Surgical Procedures*
  • Cattle
  • Coronary Angiography
  • Coronary Vessels / diagnostic imaging
  • Coronary Vessels / surgery
  • Endocarditis*
  • Humans