Advances in cerebral perfusion imaging techniques in acute ischemic stroke

J Clin Ultrasound. 2022 Oct;50(8):1202-1211. doi: 10.1002/jcu.23277.

Abstract

The application of cerebral perfusion imaging has demonstrated significant assessment benefits and an ability to establish an appropriate triage of patients with acute ischemic stroke (AIS) and large artery occlusion (LAO) in the extended time window. Computed tomography perfusion (CTP) and magnetic resonance imaging (MRI) are routinely used to determine the ischemic core, as well as the tissue at risk, to aid in therapeutic decision-making. However, the time required to transport patients to imaging extends the door-to-reperfusion time. C-arm cone-beam CT (CBCT) is a novel tomography technology that combines 2D radiography and 3D CT imaging based on the digital subtraction angiography platform. In comparison with CT or MRI perfusion techniques, CBCT combined with catheterized angiogram or therapy can serve as a "one-stop-shop" for the diagnosis and treatment of AIS, and greatly reduce the door to reperfusion time. Here, we review the current evidence on the efficacy and theoretical basis of CBCT, as well as other perfusion techniques, with the purpose to assist clinicians to establish an effective and repaid workflow for patients with AIS and LAO in clinical practice.

Keywords: C-arm cone-beam CT; acute ischemic stroke; computerized tomography; magnetic resonance; perfusion.

Publication types

  • Review

MeSH terms

  • Brain Ischemia* / diagnostic imaging
  • Cerebrovascular Circulation
  • Humans
  • Ischemic Stroke* / diagnostic imaging
  • Stroke* / diagnostic imaging