Towards differentiation of brain tumor from radiation necrosis using multi-parametric MRI: Preliminary results at 4.7 T using rodent models

Magn Reson Imaging. 2022 Dec:94:144-150. doi: 10.1016/j.mri.2022.10.002. Epub 2022 Oct 6.

Abstract

Background: It remains a clinical challenge to differentiate brain tumors from radiation-induced necrosis in the brain. Despite significant improvements, no single MRI method has been validated adequately in the clinical setting.

Methods: Multi-parametric MRI (mpMRI) was performed to differentiate 9L gliosarcoma from radiation necrosis in animal models. Five types of MRI methods probed complementary information on different scales i.e., T2 (relaxation), CEST based APT (probing mobile proteins/peptides) and rNOE (mobile macromolecules), qMT (macromolecules), diffusion based ADC (cell density) and SSIFT iAUC (cell size), and perfusion based DSC (blood volume and flow).

Results: For single MRI parameters, iAUC and ADC provide the best discrimination of radiation necrosis and brain tumor. For mpMRI, a combination of iAUC, ADC, and APT shows the best classification performance based on a two-step analysis with the Lasso and Ridge regressions.

Conclusion: A general mpMRI approach is introduced to choosing candidate multiple MRI methods, identifying the most effective parameters from all the mpMRI parameters, and finding the appropriate combination of chosen parameters to maximize the classification performance to differentiate tumors from radiation necrosis.

Keywords: Brain tumor; MRI; Multi-parametric; Radiation necrosis; mpMRI.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Brain Neoplasms* / diagnostic imaging
  • Brain Neoplasms* / radiotherapy
  • Contrast Media
  • Magnetic Resonance Imaging / methods
  • Multiparametric Magnetic Resonance Imaging*
  • Necrosis / diagnostic imaging
  • Radiation Injuries*
  • Rodentia

Substances

  • Contrast Media
  • APT