Antifouling poly(PEGMA) grafting modified titanium surface reduces osseointegration through resisting adhesion of bone marrow mesenchymal stem cells

Acta Biomater. 2022 Nov:153:585-595. doi: 10.1016/j.actbio.2022.09.058. Epub 2022 Sep 24.

Abstract

As an alternative strategy to achieve the desired bone augmentation, tenting screw technology (TST) has considerably broadened the indications for implant treatment. Titanium tenting screws are typically used in TST to maintain the space for bone regeneration. However, a high degree of osteogenic integration complicate titanium tenting screw removal and impact the bone healing micro-environment. Previous efforts have been focused on modifying titanium surfaces to enhance osseointegration while ignoring the opposite process. Due to the vital role of bone marrow mesenchymal stem cells (BMSCs) in bone regeneration, it might be feasible to reduce osseointegration around titanium tenting screws by resisting the adhesion of BMSCs. Herein, poly(ethylene glycol)methyl ether methacrylate (poly(PEGMA)) with an optimal length of PEG chain was incorporated with a Ti surface in terms of surface-initiated activators regenerated by electron transfer atom transfer radical polymerization (SI-ARGET ATRP). The cell apoptosis analysis showed that the new surface would not induce the apoptosis of BMSCs. Then, the adhesive and proliferative behaviors of BMSCs on the surface were analyzed which indicated that the poly(PEGMA) surface could inhibit the proliferation of BMSCs through resisting the adhesion process. Furthermore, in vivo experiments revealed the presence of the poly(PEGMA) on the surface resulted in a lower bone formation and osseointegration compared with the Ti group. Collectively, this dense poly(PEGMA) surface of Ti may serve as a promising material for clinical applications in the future. STATEMENT OF SIGNIFICANCE: The poly(ethylene glycol)methyl ether methacrylate (poly(PEGMA)) with an optimal length of PEG chain was grafted onto a Ti surface by surface-initiated activators regenerated by electron transfer atom transfer radical polymerization (SI-ARGET ATRP). The PEGMA surface could reduce the osteogenic integration by preventing the adhesion of cells, resulting in a lower pullout force of the modified implant and thereby desirable and feasible applications in dental surgery.

Keywords: Anti-fouling Ti surface; Bone marrow mesenchymal stem cells; Osseointegration; Titanium tenting screw.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biofouling* / prevention & control
  • Bone Marrow Cells / metabolism
  • Mesenchymal Stem Cells*
  • Methacrylates / metabolism
  • Methacrylates / pharmacology
  • Methyl Ethers* / metabolism
  • Osseointegration
  • Polyethylene Glycols / metabolism
  • Polyethylene Glycols / pharmacology
  • Surface Properties
  • Titanium / pharmacology

Substances

  • Titanium
  • polyethylene glycol methacrylate
  • Methacrylates
  • Polyethylene Glycols