State of refractive surgery with Visian ICL posterior chamber phakic lens in Spain

Arch Soc Esp Oftalmol (Engl Ed). 2023 Feb;98(2):98-104. doi: 10.1016/j.oftale.2022.06.018. Epub 2022 Sep 15.

Abstract

Objectives: To analyse the state of refractive surgery with Visian ICL phakic lens implantation in Spain, indicating the mean ranges of implanted powers, visual and refractive outcomes obtained and safety and efficacy indices.

Method: This is a population-based, cross-sectional, descriptive, analytical, retrospective, multicentre study in which each co-author collected data from at least the last 10 patients (up to a maximum of 30) with Visian ICL phakic lens implantation. One eye from each subject was randomly selected for study inclusion, and the variables analysed were: age, gender, visual acuities with and without correction pre and post-surgery, preoperative and residualrefraction, keratometry, endothelial cellular density, anterior chamber depth from endothelium, central corneal pachymetry, intraocular pressure, white-white, implanted lens (power and size), expected and achieved spherical equivalent (SEQ) post-surgery at one month after surgery.

Results: A sample of 140 eyes was obtained from 140 patients with a mean age of 31.35 ± 7.28 years. Mean preoperative SEQ was -6.33 ± 3.69D, mean CDVA was 0.96 ± 0.16, ACD was 3.30 ± 0.29 mm, WTW 12.02 ± 0.40 mm, CCT 535.03 ± 37.68 µm, ECD 2684.37 ± 313.74 cels/mm2 and IOP 14.84 ± 2.59 mmHg. 66.4% of the implanted lenses were spherical ICLs and 33.6% toric, with a mean power of -7.81 ± 4.09D and a mean cylinder of 2.27 ± 1.23D. 5.7% of the implanted lenses were hypermetropic. The mean SEQ target selected was +0.04 ± 0.27D. 48.92% of the implanted lenses were of size 13.2 mm, with the remaining 36.69, 10.79 and 3.60% being of sizes 12.6, 12.1 and 13.7 mm, respectively. At one month after surgery a residual SEQ of -0.01 ± 0.31D was obtained. The efficacy and safety indices were 1.06 ± 0.18 and 1.10 ± 0.19, respectively. The mean central vault was 508.80 ± 201.04 µm. The accuracy between the calculated SEQ and the obtained SEQ was 99.3% for spherical lenses and 88.2% for Cyl correction. The mean ECD at 1 month after surgery was 2805.53±273.30céls/mm2, which was a difference from preoperative of 0.11% (p = 0.922), similarly, the mean IOP was 13.98 ± 2.57 mmHg, which was a difference of -0.92 ± 2.80 mmHg.

Conclusions: ICL phakic lens surgery is an effective, safe and predictable procedure. There were no significant changes in endothelial cell count or intraocular pressure measurement one month after surgery.

Keywords: Cirugía refractiva; Lente fáquica; Miopía; Myopia; Phakic lens; Refractive surgery.