Substantial gradient mitigation in simulated large-scale bioreactors by optimally placed multiple feed points

Biotechnol Bioeng. 2022 Dec;119(12):3549-3566. doi: 10.1002/bit.28232. Epub 2022 Sep 26.

Abstract

The performance of large-scale stirred tank and bubble column bioreactors is often hindered by insufficient macromixing of feeds, leading to heterogeneities in pH, substrate, and oxygen, which complicates process scale-up. Appropriate feed placement or the use of multiple feed points could improve mixing. Here, theoretically optimal placement of feed points was derived using one-dimensional diffusion equations. The utility of optimal multipoint feeds was evaluated with mixing, pH control, and bioreaction simulations using three-dimensional compartment models of four industrially relevant bioreactors with working volumes ranging from 8 to 237 m3 . Dividing the vessel axially in equal-sized compartments and locating a feed point or multiple feed points symmetrically in each compartment reduced the mixing time substantially by more than a minute and mitigated gradients of pH, substrate, and oxygen. Performance of the large-scale bioreactors was consequently restored to ideal, homogeneous reactor performance: oxygen consumption and biomass yield were recovered and the phenotypical heterogeneity of the biomass population was diminished.

Keywords: bioreactor; compartment model; feed point; industrial biotechnology; mixing time; scale-up.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biomass
  • Bioreactors*
  • Oxygen*

Substances

  • Oxygen