Preoperative Assessment of Blood Vessels and Intratumoral Microbleeds in Brain Tumors Based on a 3D Contrast-Enhanced T1 -Weighted Flow-Sensitive Black-Blood Sequence

J Magn Reson Imaging. 2023 May;57(5):1543-1551. doi: 10.1002/jmri.28415. Epub 2022 Aug 30.

Abstract

Background: Three-dimensional (3D) contrast-enhanced T1 -weighted flow-sensitive black-blood (CE-T1 WI FSBB) is a newly developed black blood sequence by adding motion probing gradient pulses to gradient echo (GRE) sequences, which has important value for the preoperative assessment of tumor brain blood supply vessels and intratumoral microbleeds.

Purpose: To compare 3D CE-T1 WI FSBB and 3D contrast-enhanced fast spin echo (FSE) sequence for T1 WI for preoperative assessment of blood vessels and microbleeds in brain tumors and to investigate the correlation between visible vessels and microbleeds.

Study type: Prospective.

Subjects: One hundred and seventy-five patients with brain tumors, 65 were male, 110 were female. Including histologically confirmed 73 meningiomas, 23 schwannomas, 20 gliomas, 7 hemangioblastomas, 5 metastases, 2 lymphomas, 2 hemangiopericytomas, 2 germ cell tumors, 1 craniopharyngioma, and 1 cholesteatoma.

Field strength/sequence: A 3-T, CE-T1 WI FSBB, GRE; 3-T, CE-T1 WI, FSE.

Assessment: Three neuroradiologists counted the number of intratumoral vessels on CE-T1 WI and CE-T1 WI FSBB images separately, and they counted the number of intratumoral microbleeds on CE-T1 WI FSBB images. Brain tumors were classified into grade I, grade II, and grade IV according to the World Health Organization (WHO) grading. Differences in the ability of CE-T1 WI FSBB and CE-T1 WI to display intratumoral vessels were compared. The mean counts of three observers were used to study the correlation between vessels and microbleeds.

Statistical tests: Two-way random intraclass correlation coeficient (ICC) was used for inter-reader agreement regarding intratumoral vessel and microbleed counts, and the linear regression analysis (with F-test) was used to study the correlation between intratumoral vessels and microbleeds based on CE-T1 WI FSBB (α = 0.05).

Results: Inter-reader agreements for intratumoral vessel count on CE-T1 WI (ICC = 0.93) and CE-T1 WI FSBB (ICC = 0.92), and the agreement for intratumoral microbleed count on CE-T1 WI FSBB (ICC = 0.99) were excellent. There were statistically significant differences in intratumoral vessel counts between CE-T1 WI and CE-T1 WI FSBB using Mann-Whitney U -test: image readers could identify more intratumoral vessels on CE-T1 WI FSBB images, particularly for meningiomas, schwannomas, gliomas, and WHO grade I tumors. The number of intratumoral vessels had a significant positive effect on the number of intratumoral microbleeds (microbleeds = 5.024 + 1.665 × vessels; F = 11.51).

Data conclusion: More intratumoral vessels could potentially be identified using a 3D CE-T1 WI FSBB sequence compared to a CE-T1 WI sequence, and the number of intratumoral vessels showed a positive linear relationship with the number of intratumoral microbleeds, which might suggest that brain tumors with rich blood supply were more prone to intratumoral microbleeds.

Evidence level: 2 TECHNICAL EFFICACY: Stage 3.

Keywords: brain tumor; flow-sensitive black blood; intratumoral microbleeds; intratumoral vessels; preoperative.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Brain Neoplasms* / secondary
  • Cerebral Hemorrhage
  • Contrast Media
  • Female
  • Glioma*
  • Humans
  • Magnetic Resonance Imaging / methods
  • Male
  • Meningeal Neoplasms*
  • Meningioma*
  • Neurilemmoma*
  • Prospective Studies

Substances

  • Contrast Media