Experimental Study on the Durability of Steel Anchors for Prestressed CFRP Laminates under Accelerated Galvanostatic Corrosion

Materials (Basel). 2022 Aug 18;15(16):5665. doi: 10.3390/ma15165665.

Abstract

The novelty of the present study is to address the durability of corroded anchors for prestressing CFRP laminates. Two types of steel anchors, clamp anchors and wedge anchors, were used to prestress CFRP laminates and then subjected to steel corrosion through a galvanostatic acceleration approach, which was followed by tensile tests. Compared to clamp anchors, wedge anchors showed a superior durability performance in terms of their prestress retention, anchor efficiency, and resistance to the slippage of the CFRP laminate. After accelerated corrosion for 144 h, the clamp anchor exhibited a prestress retention of 79.1% and an anchorage efficiency of 55%, and the percentages became 9.0% and 100% for the wedge anchor. The slippage rates of the clamp anchor and the wedge anchor were 0.036 mm/kN and 0.026 mm/kN, respectively. Therefore, the wedge anchor, which exhibited higher prestress tension and anchorage efficiency, performed better than the clamp anchor. The present work provides an apparatus for exploring the corrosion-induced durability of steel anchors and experimental evidence that helps refine the provision in the guidelines for addressing anchor durability.

Keywords: accelerated corrosion; anchor efficiency; anchors; durability.