Abstract

World Rugby employs a specific drop test method to evaluate headgear performance, but almost all researchers use a different variation of this method. The aim of this study was, therefore, to quantify the differences between variations of the drop testing method using a Hybrid III headform and neck in the following impact setups: (1) headform only, with a flat steel impact surface, approximating the World Rugby method, (2 and 3) headform with and without a neck, respectively, onto a flat MEP pad impact surface, and (4) headform and neck, dropped onto an angled MEP pad impact surface. Each variation was subject to drop heights of 75-600 mm across three orientations (forehead, side, and rear boss). Comparisons were limited to the linear and rotational acceleration and rotational velocity for simplicity. Substantial differences in kinematic profile shape manifested between all drop test variations. Peak accelerations varied highly between variations, but the peak rotational velocities did not. Drop test variation also significantly changed the ratios of the peak kinematics to each other. This information can be compared to kinematic data from field head impacts and could inform more realistic impact testing methods for assessing headgear.

Keywords: Concussion; Impact method; Impact recreation; Linear accelerations; Rotational accelerations; Rugby.

MeSH terms

  • Acceleration
  • Biomechanical Phenomena
  • Craniocerebral Trauma*
  • Head
  • Head Protective Devices*
  • Humans
  • Neck
  • Rugby