Diagnostic performance of the 2021 Korean thyroid imaging reporting and data system in pediatric thyroid nodules

Eur Radiol. 2023 Jan;33(1):172-180. doi: 10.1007/s00330-022-09037-2. Epub 2022 Aug 17.

Abstract

Objectives: To evaluate the diagnostic performance of 2021 K-TIRADS biopsy criteria for detecting malignant thyroid nodules in a pediatric population, making comparisons with 2016 K-TIRADS.

Methods: This retrospective study included pediatric patients with histopathologically confirmed diagnoses. The diagnostic performance of 2021 K-TIRADS was compared with that of 2016 K-TIRADS. Simulation studies were performed by changing biopsy cut-off sizes for K-TIRADS 5 to 1.0 cm (K-TIRADS5-1.0cm) and 0.5 cm (K-TIRADS5-0.5cm), and for K-TIRADS 4 to 1.0 cm (K-TIRADS4-1.0cm) and 1.0-1.5 cm (K-TIRADS4-1.0~1.5cm). Subgroup analysis was performed in small (< 1.5 cm) and large nodules (≥ 1.5 cm).

Results: Two hundred seventy-seven thyroid nodules (54.9% malignant) from 221 pediatric patients were analyzed. All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. Compared with 2021 K-TIRADS5-1.0cm, 2021 K-TIRADS5-0.5cm showed lower specificity (51.6% vs. 47.9%; p = 0.004) but higher sensitivity (77.2% vs. 90.3%; p < 0.001) and accuracy (62.7% vs. 68.9%; p < 0.001). Compared with 2021 K-TIRADS4-1.0cm, 2021 K-TIRADS4-1.0~1.5cm showed higher specificity (44.9% vs. 47.9%; p = 0.018) without significant difference in other diagnostic measures. Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity (34.0% vs. 67.3%; p < 0.001) while maintaining specificity (89.4% vs. 88.2%; p = 0.790) in small nodules, and higher specificity (5.9% vs. 25.4%; p < 0.001) while maintaining sensitivity (100% vs. 98.7%; p = 0.132) in large nodules.

Conclusions: In pediatric patients, 2021 K-TIRADS showed superior diagnostic accuracy to 2016 K-TIRADS, especially with a biopsy cut-off of 0.5 cm for K-TIRADS 5 and 1.0-1.5 cm for K-TIRADS 4.

Key points: • All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. • 2021 K-TIRADS with cut-off size for K-TIRADS 5 of 0.5 cm showed lower specificity but higher sensitivity and accuracy than that of 1.0 cm. • Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity while maintaining specificity in small nodules, and higher specificity while maintaining sensitivity in large nodules.

Keywords: Biopsy; Pediatrics; Thyroid; Thyroid neoplasm; Ultrasonography.

MeSH terms

  • Child
  • Humans
  • Republic of Korea / epidemiology
  • Retrospective Studies
  • Risk Assessment / methods
  • Thyroid Neoplasms* / pathology
  • Thyroid Nodule* / diagnostic imaging
  • Ultrasonography / methods