The Influence of Surgeon Caseload and Usage on the Long-Term Outcomes of Mobile-Bearing Unicompartmental Knee Arthroplasty: An Analysis of Data From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man

J Arthroplasty. 2023 Feb;38(2):245-251. doi: 10.1016/j.arth.2022.08.011. Epub 2022 Aug 11.

Abstract

Background: Unicompartmental knee arthroplasty (UKA) revision rates are variable and known to be influenced by a surgeon's caseload (number of UKAs performed annually) and usage (UKA as a proportion of overall knee arthroplasty practice). It is not known which is more important. We explored the influence of caseload and usage on cemented and cementless UKA.

Methods: A total of 34,277 medial Oxford UKAs (23,707 cemented and 10,570 cementless) from the National Joint Registry were analyzed. UKAs were subdivided by the following: (1) surgeon caseload, into low (<10 UKAs/y) and high (≥10 UKAs/y) categories; and (2) usage, into low (<20%) and high (≥20%) categories. The 10-year revision rates were compared.

Results: The 10-year survival of the low-caseload/low-usage cemented and cementless UKA was 82.8% (CI 81.6-83.9) and 86.2% (CI 72.1-93.4), respectively. The 10-year survival of the high-caseload/high-usage cemented and cementless UKA was 90.0% (CI 89.2-90.6) and 93.3% (CI 91.3-94.8), respectively. For cemented UKA, the high-caseload/high-usage group had lower revision rates (hazard ratio [HR] 0.57, CI 0.52-0.63, P < .001) compared to the low-caseload/low-usage group. The high-caseload/low-usage (HR 0.74, CI 0.66-0.83, P < .001) and the low-caseload/high-usage (HR 0.86, CI 0.74-0.99, P = .04) groups also had lower revision rates than the low-caseload/low-usage group.

Conclusion: Mobile-bearing UKA revision rates improve with both increasing surgeon UKA caseload and usage. Surgeons using cemented UKA who have usage ≥20% and caseload ≥10/year had a 10-year survival of 90%. Higher survivorship was associated with higher caseload, higher usage, and cementless fixation.

Levels of evidence: III.

Keywords: caseload; fixation; revision; unicompartmental knee arthroplasty; usage.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Arthroplasty, Replacement, Knee*
  • England
  • Humans
  • Knee Prosthesis*
  • Northern Ireland / epidemiology
  • Osteoarthritis, Knee* / surgery
  • Prosthesis Failure
  • Registries
  • Reoperation
  • Surgeons*
  • Treatment Outcome
  • Wales