Biomechanical responses of human lumbar spine and pelvis according to the Roussouly classification

PLoS One. 2022 Jul 29;17(7):e0266954. doi: 10.1371/journal.pone.0266954. eCollection 2022.

Abstract

Background: Few studies have analyzed the different biomechanical properties of the lumbar with various morphological parameters, which play an important role in injury and degeneration. This study aims to preliminarily investigate biomechanical characteristics of the spine with different sagittal alignment morphotypes by using finite element (FE) simulation and in-vitro testing.

Methods: According to the lumbar-pelvic radiographic parameters of the Chinese population, the parametric FE models (L1-S1-pelvis) of Roussouly's type (1-4) were validated and developed based on the in-vitro biomechanical testing. A pure moment of 7.5 Nm was applied in the three anatomical planes to simulate the physiological activities of flexion, extension, left-right lateral bending and left-right axial rotation.

Results: The sagittal configuration of four Roussouly's type models had a strong effect on the biomechanical responses in flexion and extension. The apex of the lumbar lordosis is a critical position where the segment has the lowest range of motion among all the models. In flexion-extension, type 3 and 4 models with a good lordosis shape had a more uniform rotation distribution at each motor function segment, however, type 1 and 2 models with a straighter spine had a larger proportion of rotation at the L5-S1 level. In addition, type 1 and 2 models had higher intradiscal pressures (IDPs) at the L4-5 segment in flexion, while type 4 model had larger matrix and fiber stresses at the L5-S1 segment in extension.

Conclusion: The well-marched lordotic type 3 lumbar had greater stability, however, a straighter spine (type 1 and 2) had poor balance and load-bearing capacity. The hypolordotic type 4 model showed larger annulus fiber stress. Therefore, the sagittal alignment of Roussouly's type models had different kinetic and biomechanical responses under various loading conditions, leading to different clinical manifestations of the lumbar disease.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biomechanical Phenomena / physiology
  • Finite Element Analysis
  • Humans
  • Lordosis*
  • Lumbar Vertebrae / diagnostic imaging
  • Lumbar Vertebrae / physiology
  • Pelvis / diagnostic imaging
  • Pelvis / physiology
  • Range of Motion, Articular / physiology
  • Spinal Fusion*
  • Weight-Bearing / physiology

Grants and funding

This research was supported by National Natural Science Foundation of China (No. 11972065), Beijing Natural Science Foundation (L202006). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.