Diagnostic accuracy of cardiac computed tomographic angiography and transesophageal echocardiography in evaluation of patients with prosthetic paravalvular leakage

Echocardiography. 2022 Aug;39(8):1122-1130. doi: 10.1111/echo.15428. Epub 2022 Jul 24.

Abstract

Purpose: Computed Tomography (CT) scan has been well addressed to provide diagnostic information for patients with prosthetic heart valve (PHV) dysfunction. However, its role in the assessment of patients with prosthetic paravalvular leakage (PVL) has not been studied thoroughly. So, this study was conducted to assess the feasibility, reproducibility, and accuracy of CT for diagnosis of prosthetic PVL using surgical findings as the reference standard.

Materials and methods: This was a prospective cohort study that was conducted on 26 consecutive patients with suspected prosthetic PVL who underwent both transesophageal echocardiography (TEE) and 64-slice ECG-gated CT. The gold standard was the intraoperative findings. Surgery was performed on 26 patients.

Results: There was an excellent degree of agreement between CT and intraoperative findings for diagnosis, localization of prosthetic PVL. The perimeter of prosthetic PVL measured by CT was strongly correlated with echocardiographic severity of PVL by TEE (Spearman's Correlation Coefficient, r = .83, p = .0014).

Conclusion: This study demonstrates that cardiac CT showed comparable diagnostic accuracy to TEE and intraoperative findings for the detection, localization, and assessment of severity of prosthetic PVL. Moreover, CT was shown to be useful in detection of other findings related to prosthetic cardiac valves.

Keywords: ECG gated computed tomography; prosthetic heart valve dysfunction; prosthetic paravalvular leakage; transesophageal echocardiography.