FIDELITY: A quality control system for droplet microfluidics

Sci Adv. 2022 Jul 8;8(27):eabc9108. doi: 10.1126/sciadv.abc9108. Epub 2022 Jul 8.

Abstract

Droplet microfluidic systems have been widely deployed to interrogate biological and chemical systems. The major limitations of these systems are the relatively high error rates from critical droplet manipulation functions. To address these limitations, we describe the development of FIDELITY (Flotation and Interdigitated electrode forces on Droplets to Enable Lasting system IntegriTY), a highly sensitive and accurate size-based droplet bandpass filter that leverages the natural buoyancy of aqueous droplets and highly localized dielectrophoretic force generated by interdigitated electrode arrays. Droplet manipulation accuracies greater than 99% were achieved at a throughput of up to 100 droplets/s and separation of droplets that differed in diameter by only 6 μm was demonstrated. Last, the utility of FIDELITY was demonstrated in a droplet size quality control application and also in a droplet-based in vitro transcription/translation workflow. We anticipate FIDELITY to be integrated into a broad range of droplet microfluidic configurations to achieve exceptional operational accuracy.